Schier GB-50 Скачать руководство пользователя страница 1

Part #: 4025-009-01
Find these instructions online at: schierproducts.com/gb-50

Contents

Special Precautions  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-3
Getting to Know the GB-50 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-10

INSTALLATION GUIDE

GB-50

   

50 GPM Great Basin

 Indoor/Outdoor Grease Interceptor

913-951-3300  |  schierproducts.com

© Copyright 2020 Schier Products Company, 09/02/2020

Содержание GB-50

Страница 1: ...rproducts com gb 50 Contents Special Precautions 2 3 Getting to Know the GB 50 4 Installation 5 10 INSTALLATION GUIDE GB 50 50 GPM Great Basin Indoor Outdoor Grease Interceptor 913 951 3300 schierproducts com Copyright 2020 Schier Products Company 09 02 2020 ...

Страница 2: ... leading to eventual failure cold water supply line high temperature effluent 150º F approved backflow prevention assembly DTV drain water tempering valve directly connected indirectly connected ODOR ALERT Interceptor is not a sewer gas trap All upstream fixtures must be trapped ODOR ALERT Do not install air gap on outlet side of interceptor Provide at least 12 clearance above unit for routine maint...

Страница 3: ... of the unit Do not partially support unit or suspend unit using metal U channel to create a trapeze concrete floor Hydrostatic Pressure Slabs When installed under a hydrostatic slab slab designed to withstand upward lift usually caused by hydrostatic pressure interceptor must be enclosed in a watertight concrete vault concrete slab subject to hydrostatic pressure watertight concrete vault DO NOT ...

Страница 4: ...t 11 Inlet diffuser cover white 12 Inlet diffuser 13 Inlet diffuser retaining nut 14 Inlet diffuser foot retaining nut 15 Inlet diffuser foot 16 Inlet bulkhead connection 4 FPT 17 4 plain end fitting x2 18 Composite cover bolts and washers x4 19 Bolted composite cover optional 20 Air relief visual access 21 Outlet diffuser retaining nut 22 Outlet diffuser 23 Outlet diffuser foot retaining nut 24 O...

Страница 5: ...stics Remove covers For base unit testing fill with water to just above the highest connection Inspect unit connections and gaskets for leaks Check water level at specific time intervals per local code Fill Line Excavate hole at least 12 larger than interceptor on all sides and 6 deeper than tank bottom Lay a level bed of well packed crushed aggregate approximately 3 4 size rock or sand with no fi...

Страница 6: ...let diffuser side outlets only 3c Cap unused connections all configurations Side Outlet Go to Step 3b Straight Through Go to Step 3c Remove safety star insert leave tethered to unit Unscrew diffuser retaining nut and remove outlet diffuser Unscrew diffuser foot retaining nut and remove outlet diffuser foot Rotate diffuser toward chosen outlet replace foot ensuring it will point to the back wall of...

Страница 7: ...om the parts bag Slide inlet diffuser cover into top of inlet diffuser and rotate clockwise until cartridge drops onto inlet diffuser cover retainer pins Continue rotating clockwise until pins are fully seated inlet diffuser cover retainer pin cartridge receiver slot 4a Install inlet diffuser cover For easy inlet diffuser cover removal in deep burial installations 1 1 2 PVC SCH 40 pipe may used as...

Страница 8: ...ion and set level Mechanically couple inlet and outlet drainage lines to unit Do not solvent weld Ensure all upstream fixtures are trapped Vent per local code Installation of 2 way cleanout tees to grade by others is recommended for buried installations Outlet 2 way cleanout tee Inlet BURIED INSTALLATION COUPLING DETAIL Drain line Flexible coupling Plain end fitting Bulkhead fitting 4 FPT 4 FPT 4 ...

Страница 9: ...termine riser height needed 7a See instructions included with FCR2 Loosen the cover adapter upper band clamp using 7 16 nut driver bit Adjust cover adapter heights as needed Maintain a minimum 2 1 2 insertion depth Tighten upper band clamp to 5 8 ft lbs of torque using 7 16 nut driver bit If required cover adapters may now be tilted up to 10º in any direction using gasket flexibility 7c Make final...

Страница 10: ...Schier model AK1 anchor kit Max water table height for direct burial Vehicular Traffic Areas Minimum 8 thick concrete slab with rebar required Thickness of concrete around covers to be determined by specifying engineer If traffic loading is required the concrete slab dimensions shown are for guideline purposes only Concrete to be 28 day compressive strength to 4 000 PSI Use No 4 rebar ø 1 2 grade ...