9
Installation Instructions
SW-DW ADJUSTABLE STARTER SECTION
The protruding male spigot of the adaptor slides down inside the female socket of the Prima
Smooth pipe and the socket of the Prima Smooth pipe slides within the conical section of the
starter adaptor, to a maximum length of 75mm into the cone with a minimum of 15mm to
ensure a secure connection. This maximum length of 75mm will leave sufficient space within
the adaptor to allow for thermal expansion of the single wall pipe and also to allow for the
connecting flue pipe to be removed without cutting, if the appliance has to be moved for
servicing.
100
15 min
Prima
Smooth
SW-DW
Adjustable
Starter
Section
75 max
ADAPTOR ECO ICID TO PRIMA SMOOTH
This component is used to convert from Prima Smooth
Connecting Flue Pipe to the Eco ICID System Chimney.The
protruding liner of the adaptor should be pushed down inside
the female socket of the connecting flue pipe, with the male
collar pointing upwards.
ADAPTOR FROM PRIMA SMOOTH TO ICS
This component is used to convert from Prima Smooth
Connecting Flue Pipe to the ICS System Chimney. The
protruding liner of the ICS should be pushed down inside the
female socket of the Prima Smooth.
ADAPTOR FROM PRIMA SMOOTH TO TECNOFLEX PLUS
This component is used to convert from Prima Smooth
Connecting flue pipe to TecnoFlex Plus. The end of the
TecnoFlex Plus should be trimmed to allow the adaptor to
be screwed in a clockwise direction onto the TecnoFlex Plus.
Care should be taken to ensure that the TecnoFlex Plus liner
is fully engaged into the inner sleeve of the adaptor, thereby
protecting the cut edges of the TecnoFlex Plus.