background image

Item

 Submenu

1. Installer Setup

1.  ID Code                         [1]

2.  Unlock Timing               [05]

3.  Unlock Output               [0]

4.  Card Memory                [0]

5.  Doorplate Mode

6.  Audio Options ...

7.  Parameters ...

8.  Installer Code ...

9.  Default ...

2. Setup

1.  Language                     [1]

2.  Tone Select                  [03]

3.  Tone Volume                [08]

4.  Unlock Code                [1111]

5.  Display Mode 

6.  Clock ...

7.  Setup Code ...

8.  About ...

9.  Default ...

3. Card Manage

1.  Add Card ...

2.  Delete By Card

3.  Delete By M.code

4.  Cards Information

5.  Format

4. Online Monitors

To search the online monitors,input the monitor code 

number to search

5. Online Devices

To search the online door stations.Max.4 door station 

can be searched

6. Voltage Measure

To check the voltage of the monitor,note that the 

monitor must be online.

Table 1:

Содержание DMR18

Страница 1: ...tion Please read this manual carefully before using the product you purchase and keep it well for future use We reserve the right to modify the specification in this manual at any time without notice 1 2 3 6 5 4 7 8 9 0 RF CARD ...

Страница 2: ...V L2 1 2 3 6 5 4 7 8 9 0 RF CARD 1 2 3 1 2 3 12V 12VDC power output LK GND power ground LK COM common contact of the Relay NO normally open contact of the Relay refer to DT technical guide for Lock connection detail informations EB Exit button connection port EB Exit buton connection port JP LK For electronic lock safety type setting refer to Door Station Lock Connections T R USB RS485 communicati...

Страница 3: ...ach screws to fix the metal box Attach the unit to the rainy cover correctlly Attach the baffle to protect the unit from droping The last view for all mounting The view for rainy cover after mounted Adjust the camera angle and attach the metal to the panel and wire correctly Camera angle ...

Страница 4: ... for Power to Unlock safety type Normally open mode set to 2 3 position for Power off to Unlock type Normally closed mode Note that the unlock relay mode is set on the Parameter tab of DT CONFIG software If different unlocking time is needed to be configured the DT CONFIG software can be used to change the Unlock Timing on the Parameter tab see the program section JP_LK 12V 300mA Jumper set to 1 2...

Страница 5: ...12 Vdc additional power supply for the lock is needed The power supply for the lock must be less than 48Vdc 1 5A The Jumper must be removed when using external power supply The default setting is Power to Unlock type Normally open mode if use Power off to Unlock type change the Unlock Relay mode to Normally closed mode Note that the unlock relay mode is set on the Parameter tab of DT CONFIG softwa...

Страница 6: ...r Station is in standby press key Press 2 key to exit out the debug state input 9008 then input the Admin Code 66666666 by default Debug State menu is launched 9 0 0 8 Please Input Password 1 2 3 6 5 4 7 8 9 0 RF CARD D e b u g S t a t e 1 To o l s 0 R e d i a l 2 E x i t s 3 About Debug Tools During working at Debug State press 1 to enter tools page Debug Tools overviews is shown as below 1 I n s...

Страница 7: ...ock Code 1111 5 Display Mode 6 Clock 7 Setup Code 8 About 9 Default 3 Card Manage 1 Add Card 2 Delete By Card 3 Delete By M code 4 Cards Information 5 Format 4 Online Monitors To search the online monitors input the monitor code number to search 5 Online Devices To search the online door stations Max 4 door station can be searched 6 Voltage Measure To check the voltage of the monitor note that the...

Страница 8: ...he card is saved in door station If set to 1 the card is saved in DT IPC 0 Doorplate Mode To set the calling mode If set to 0 it s the auto mode that means the calling will be activated directly after inputting 2 digits code If set to 1 it s the manual mode that means you should press button to activate the calling after inputting the code 0 Auto mode Audio Options To set the talking mode If set t...

Страница 9: ... at the same time If set to 0 unlock function is disabled Set to 1 unlock is enable Set to 2 unlock is enable and close at once Set to 3 unlock is enable and close in 5s 1 Ring Numbers To show ring times when door station calls monitor 4 options for choice If set to 0 ring once If set to 1 ring twice If set to 2 ring three times If set to 3 cycle ring 1 NameList Display Mode To show the namelist d...

Страница 10: ...M DD YY Time format if set to 0 time format is 24 hour standard If set to 1 time format is12 hour standard Setup Code To change the Program Code 88888888 About 1 Hardware version To show the Door Station including ACS hardware information 2 Software version To show the Door Station including ACS software information 3 Manufacture Date To show the manufacturing date 4 Dialing Counts To show the cal...

Страница 11: ...page to call the desired flat Residents can open the door by using their unique Unlock Code four digit PIN code If the door station is in standby mode press key then input the four digit unlock to open the door Please refer to part 5 section 7 How to use code unlock function for more detail information 5 About Default Set The Default Set is very important When the door station miss up the settings...

Страница 12: ...s 6 Vo l t a g e M e a s u r e Pres NO to select Back Tools Back Please Input Password Save 9 D e f a u l t Press Input 8002 then input Setup Code or Admin Code 88888888 or 66666666 by default Press 2 to enter tone select item 6 Change Ring Tone There are 12 different ringtones If door station runs as Debug State you can press 1 2 Setup 2 Tone Select to enter tone setting page If it runs as Normal...

Страница 13: ...r p l a t e M o d e 6 A u d i o O p t i o n s 7 P a r a m e t e r s 9 D e f a u l t Press1 9 to select Back Installer Setup 1 To o l s 8 I n s t a l l e r C o d e 1 I n s t a l l e r S e t u p 2 S e t u p 3 C a r d M e m o r y 4 O n l i n e M o n i t o r s 5 O n l i n e D e v i c e s 6 Vo l t a g e M e a s u r e Pres NO to select Back Tools Back Save 8 I n s t a l l e r C o d e In Debug State pres...

Страница 14: ... press to update 10 User Card Management This section explains how to configure the key fob function on DMR18 The key fob is used to open the lock Total 1000 key fobs can be registered with one door station When swiping the fob to the door station the distance must be less than 3 centimeter Key Fobs must be registered on the Door station that can be used to open the door Register the Key Fobs All ...

Страница 15: ...registered again to become a valid User Card User Key Fob There are two ways to delete User Cards User Key Fobs 1 Delete by card show the unwanted card s when the Door station is in Delete Card Mode 2 Delete by room number delete all the registered User Cards related to that room number 1 A d d C a r d Back Save Please Input Room Code 1 A d d C a r d Back Save Show the card 0 1 1 A d d C a r d Bac...

Страница 16: ...sword 11 Change Door Station Language It s convenient to change the user interface for DMR18 Just put the config files to the SD card and by means of the digital keypad of door station only 30 seconds is needed to update L1 T R CN LK T R J KMB JP LK Bus Insert SD card SD Card Slot EB EB N O LK LK 12V L2 1 2 3 1 2 3 Step 1 Insert the SD card which is contained config files into the SD card slot whe...

Страница 17: ...Dutch 8107 Portuguese 8108 S Chinese 8109 T Chinese 8110 Greek 8111 Turkish 8112 Polish 8113 Russian 8114 Slovakia 8115 Hungray 8116 Czech 12 Search online door stations and monitors Online Search is a very useful function that can help the installer to easily check the connectivity of all the Monitors Please note Online does not mean via the internet Please refer to the followings D e b u g S t a...

Страница 18: ... is designed to have digital keypad and big TFT screen Its namelist was shown on the screen and customer can do the calling operation through the digital keypad guided by Namelist on the screen 2 types of namelist can be shown on the screen DT Config namelist and Simulate namelist Enter namelist page Check online monitors Send namelist to monitors Press 9 in standby mode to display the user nameli...

Страница 19: ...4V Powered by DT DPS Camera Lens 1 4 ACS 4T image sensor with DSP processor Power consumption Standby 3W Working status 9W Screen 3 5 inch TFT Resolution 320 R G B X240 pixels Video signal CCIR EIA Optional Wiring 2 wires non polarit ...

Страница 20: ...DT ENG DMR18 V1 2011S0621 ...

Страница 21: ...Anleitung für DT27 25 692 TD7 Videostationen ManualDT69 TDXXSerie DE Schick2012 ...

Страница 22: ...eräte vor Feuchtigkeit zu hohen Temperaturen und Staub Befestigen Sie den Monitor in einer Höhe von ca 160 cm um eine optimale Sicht auf den Monitor zu gewährleisten Befestigen Sie die mitgelieferte Halteplatte mit den Schrauben an der Wand und hängen Sie den Monitor ein Anleitung für Innenstation DT27 SD TD7 Die optimale Montagehöhe für Ihren Monitor beträgt 145 160 cm Befestigen Sie die Haltepla...

Страница 23: ...ntage und die Uhrzeit Betätigen Sie den Bildschirm erneut und es erscheint das Hauptmenü auf den Schirm Manual Monitor Zur manuellen Auswahl Ihrer Außenstation es können hier bis zu 4 Türstationen ausgewählt und einzeln selektiert werden Auto Monitor Der Es werden alle Verfügbaren Außenstation oder und Kameras angezeigt im einstellbaren Intervallen Intercom Bei dieser Funktion erreichen Sie das In...

Страница 24: ...erkom Funktion und für die Türklingel einzustellen Sie haben hier 12 unterschiedliche Melodien zur Verfügung Dur berühren der entsprechenden Melodie auf den Bildschirm wird selbige abgespielt Dur betätigen des Exit Save Ikons wird die Melodie ausgewählt und abgespeichert Türstation Kamera auswählen Wenn sie im Standby den Talk Knopf oder im Menü den Icon Monitor betätigen öffnet sich der Bildschir...

Страница 25: ...ommen werden Einstellung Klingellautstärke Sie können über den Menüpunkt Klingellautstärke die konfigurieren Im Menüpunkt Night Ring Volume können sie die Nachtschaltung aktivieren und einstellen min Lautstärker ist 0 aus die Zeiten sind fix von 18 06 Uhr Datum und Zeit einstellen Geben sie über das Zahlenbild die Zeit und das Datum an löschen mit bestätigen mit oder mit Save Exit Monitoring zeit ...

Страница 26: ... 1 14 oder bei DT592 und 598 2 Fam 1 14 und 15 32 In Verbindungen mit den Türstationen DT591 592 und 598 ist diese Einstellung nicht notwendig das die Slave Adressen über den DIP Code des Monitors Rückseite Codes 1 15 oder 16 28 eingestellt werden Code 8010 Set lock Code 0 Bitte diese Einstellung so lassen Es liegt Spannung am Schloss an wenn oder wird potentialfrei geschlossen je an Anschluss Mod...

Страница 27: ...hkeiten extra Klingelknopf anschließbar Der Klingeltaster wird an den Monitor für den Etagenruf angeschlossen Der Monitor klingelt in der für den Etagenruf eingestellten Melodie der Bildschirm ist aus extra Klingel Es kann ein extra Gong mit einer Leistungsaufnahme von 12V 300 mA DC angeschlossen werden Selbiger klingelt bei betätigen der Außenstation und bei betätigen des Etagenrufs so lange bis ...

Страница 28: ...ie bitte Entsorgen sie das Produkt am Ende seiner Lebensdauer gemäß den geltenden gesetzlichen Vorschriften Sie können das Produkt an jeder Kommunalen Sammelstelle für Altgeräte unentgeltlich zur Umwelt und Fachgerechten abgeben IX Hinweis zum Batteriegesetz Im Zusammenhang mit dem Vertrieb von Batterien oder mit der Lieferungvon Geräten die Batterien enthalten ist der Verkäuferverpflichtet Sie au...

Страница 29: ...deten Symbole haben folgende Bedeutung Batterie darf nicht in den Hausmüll gegeben werden Pb Batterie enthält mehr als 0 004 Masseprozent Blei Cd Batterie enthält mehr als 0 002 Masseprozent Cadmium Hg Batterie enthält mehr als 0 0005 Masseprozent Quecksilber Schick Handel Ron Schick Schick Handel Max Klinger Strasse 2 04425 Taucha Tel 034298 126190 Fax 034298 13109 Funk 0172 3644099 USt ID Nr DE1...

Страница 30: ...Anleitung für DT27 DT21 25 692 SD TD7 Videostationen ManualDT69SD TDXXSerie DE Schick2010 ...

Страница 31: ...Geräte vor Feuchtigkeit zu hohen Temperaturen und Staub Befestigen Sie den Monitor in einer Höhe von ca 160 cm um eine optimale Sicht auf den Monitor zu gewährleisten Befestigen Sie die mitgelieferte Halteplatte mit den Schrauben an der Wand und hängen Sie den Monitor ein Anleitung für Innenstation DT27 SD TD7 Die optimale Montagehöhe für Ihren Monitor beträgt 145 160 cm Befestigen Sie die Haltepl...

Страница 32: ... Kalender angezeigt Datum Wochentage und die Uhrzeit Betätigen Sie den Bildschirm erneut und es erscheint das Hauptmenü auf den Schirm Manual Monitor Zur manuellen Auswahl Ihrer Außenstation es können hier bis zu 4 Türstationen ausgewählt und einzeln selektiert werden Auto Monitor Der Es werden alle Verfügbaren Außenstation oder und Kameras angezeigt im einstellbaren Intervallen ...

Страница 33: ...nnen Memory Playback Anzeigen der gespeicherten Bilder immer 4 Stück Verfügbare Funktionen löschen vor zurück alles löschen ins Hauptmenü Album Hier können Photos die auf der SD Karte nicht im Lieferumfang 2GB gespeichert sind angezeigt werden Über den Ikon Multimedia Album Options kann die Abspieldauer der Albumanzeige eingestellt werden User Setup Hier könne Einstellungen wie Lautstärke der Klin...

Страница 34: ...bgespeichert Bildspeicher Wiedergabe und Einstellung Memory Playback Anzeigen der gespeicherten Bilder immer 4 Stück Verfügbare Funktionen löschen vor zurück alles löschen ins Hauptmenü Bilder können manual während des Gesprächs aufgenommen werden oder ja nach Einstellung werden 1 4 8 Bilder aller 1 5 Sekunden aufgenommen Das erste Bild wird nach Aufbau der Verbindung nach 3 s erstell Um die Anzah...

Страница 35: ...gelegt speichert die Anlage automatisch auf SD Dazu muss die Aufnahmefunktion an Ihrer Anlage aktiviert werden Nun wird bei jeden Klingeln die Aufnahme gestartet Experten Einstellung Über die Betätigung des Unteren Icon About oder Schick Handel Logoi werden die Systemdaten Ihres Monitors angezeigt Berühren Sie den Bildschirm für 2 Sekunden und sie kommen in das Menü Installations Einstelllungen Ac...

Страница 36: ...rbrochen Standart nicht verwendet Code 8021 8029 Öffnungsdauer des Türöffners 1 9 Sekunden Code 8004 Wenn Sie den Monitor im Mehrfamilienhaus als Pförtner oder Wächter Hausmeister festlegen wollen direkte Anwahl über Guard Unit Call möglich 8005 Standarteinstellung nicht als Pförtner 8006 Diese Einstellung bitte verwenden wenn der Monitor als Slaver verwendet wird und beim betätigen der Klingel ei...

Страница 37: ...Klingeltaster wird an den Monitor für den Etagenruf angeschlossen Der Monitor klingelt in der für den Etagenruf eingestellten Melodie der Bildschirm ist aus extra Klingel Es kann ein extra Gong mit einer Leistungsaufnahme von 12V 300 mA DC angeschlossen werden Selbiger klingelt bei betätigen der Aussenstation und bei betätigen des Etagenrufs so lange bis der Monitor schliesst oder bis das Gespräch...

Страница 38: ...rodukt an jeder Kommunalen Sammelstelle für Altgeräte unentgeltlich zur Umwelt und Fachgerechten abgeben IX Hinweis zum Batteriegesetz Im Zusammenhang mit dem Vertrieb von Batterien oder mit der Lieferungvon Geräten die Batterien enthalten ist der Verkäuferverpflichtet Sie auf folgendes hinzuweisen Sie sind zur Rückgabe gebrauchter Batterien als Endnutzergesetzlich verpflichtet Sie können Altbatte...

Страница 39: ...haben folgende Bedeutung Batterie darf nicht in den Hausmüll gegeben werden Pb Batterie enthält mehr als 0 004 Masseprozent Blei Cd Batterie enthält mehr als 0 002 Masseprozent Cadmium Hg Batterie enthält mehr als 0 0005 Masseprozent Quecksilber ...

Отзывы: