ITEM
PART NO.
DESCRIPTION
QTY.
1
3424
Handle, Front
1
2
7336
Machine Screw, Blk 4
3
3426
Support Tank
1
4
6977
Machine Screw, Blk 4
5
6037
Kep Nut, Blk
8
6
3439
Axle
1
7
6869
Wheel
2
8
6870
Push Nut
2
9
7333
Spacer
2
OPERATING INSTRUCTIONS
UNPACKING
1.
Remove all protective material which may have
been applied to the heater for shipment.
2.
Remove the heater from carton
3.
Check the heater for possible shipping damage.
If any damage is found immediately notify the
dealer from whom you purchased the heater.
ASSEMBLY
(For 100,000 and 150,000 BTU/hr
models only)
Wheel and handles are found in the shipping carton
along with mounting hardware. The wheels, axle and
mounting hardware are in a plastic package. Tools
required are a 5/16" nutdriver, 3/8" open or adjustable
wrench and hammer.
1.
Slide the axle (6) through the wheel support
frame (3). Install bushing (9) and wheels (7) on the
axle.
IMPORTANT: The extended hub of the wheel
should be positioned toward the wheels support
frame. Position the cap nuts (8) on the axle
ends and gently tap with a hammer to secure.
2.
Position the heater on the wheel support frame
assembly with the exit end over the wheels.
3.
Use four screws (4) and nuts (5) to attach the
front handle (1) to the top of the tank flange. The
screws will go through the front handle, the tank
flange and the wheel support frame. Install the
nuts finger-tight-only.
IMPORTANT: Do not tighten nuts until Step 5.
4.
Using four screws (2) and nuts (5) install the tank
to support (1) as outlined in Step 3.
5.
Tighten all nuts.
OPERATION
TO FUEL
IMPORTANT: Before filling fuel tank the first time or after
extended storage periods drain the fuel tank of any
moisture or condensation.
Fill the fuel tank with clean kerosene, No. 1 fuel oil or No.
1 diesel fuel only. Kerosene is recommended for use
when the temperature drops below zero degrees
fahrenheit (-18
o
Celsius). In extremely cold weather,
condensation may develop in the tank and it is recom-
mended that a tablespoon of de-icer be added for each
gallon (4 liters) of fuel in the tank.
When filling the heater use at least 2 gallons (8 liters)
of fuel. Be sure heater is level and do not overfill. Use
a funnel or can with a long fill spout.
WARNING: To avoid fire, wipe up any spilled fuel
immediately.
TO LOCATE
WARNING: To avoid fire, place the unit in a level location
away from volatile substances and at a safe distance
from combustible materials. Adequate ventilation is
essential. Refer to the SAFETY PRECAUTION page for
advice on adequate ventilation.
Not suitable for use on wood floors or other combus-
tible materials. When used the heater should rest on
suitable insulating material at least 1 inch thick and
extending 3 feet or more beyond the heater in all
directions.
If at any time the heater should fail to start, smoke
excessively or fire intermittently, unplug it immediately
and consult a qualified service person.
TO START
K50: Plug the heater into a grounded outlet.
K100/K150: Turn thermostat to lowest setting. Plug
heater into a grounded outlet. Turn thermostat to
highest setting (heater will start). Adjust thermostat to
desired setting. Heater will cycle on/off, as heat is
required.
In cold weather, starting may be improved by holding a
finger over the end of the pressure adjusting screw
until the heater starts. This unit is equipped with a
circuit breaker located near the power cord. If the unit
does not start, check to see that the reset is pressed in.
TO STOP
K50: Unplug the heater.
K100/K150: For a short duration shutdown, where
temperatures will remain above 0
o
F, turn thermostat to
"off" position. For extended shutdown, or where the
temperature can go below 0
o
F unplug the heater.
TO RESTART
1.
Wait 5 minutes.
2.
Push reset button
3.
If heater continues to cycle off on flame safety,
see a service person.
Page 3
Содержание 50,000 BTU/HR K50-FA SPC-K50
Страница 6: ...Page 7 K Heaters ...