5
– FUNCTIONING AND USE
COD.150Z230.B.2021
EN
THE PRESENT MANUAL BELONGS TO -
Schenker Italia
- ALL RIGHTS RESERVED
29
5. FUNCTIONING AND USE
5.1 Command description
REMOTE CONTROL PANEL
Fig. 5.1
KEYBOARD FEATURES
The panel keyboard has a total of 2 push buttons. The functions of the buttons are:
ON/OFF
Used to start and stop the pumps of the system.
FLUSHING
Used to activate the electrovalve and let the system rinse with fresh water.
5.1.1 Alarms description
The system has different types of alarm, recognizable by the flashing of the two LEDs on the pushing buttons.
If the alarms occur the controller immediately stops the unit:
•
Unit stalled:
the pressure is under the threshold value during the start
– the system goes on alert after
5 seconds and the pushing buttons flash 2 times quickly;
•
Underpressure
: the pressure drops under the threshold value during the functioning
– the system
goes on alert and the pushing buttons flash 3 times quickly.
•
Overpressure
: the pressure raises over the threshold value during the functioning
– the system goes
immediately on alert and the pushing buttons flash 4 times quickly.
•
Low battery
: power supply is not sufficient - the system goes immediately on alert and the pushing
buttons flash 5 times quickly.
•
Control failure
: the pressure transducer is faulty or not properly connected - the system goes
immediately on alert and the pushing buttons flash 6 times quickly.
The alarms has to be stopped by pressing the button ON/OFF; then it is necessary to recognize and
eliminate the problem before starting again the watermaker.
5.2 First start-up procedure
The first start up procedure is necessary to start a new system or after a filter replacement or a chemical
washing.
The start-up procedure is mainly aimed to purge the air separately from the unit and the 2 pumps.