Schauer JAC0512 Скачать руководство пользователя страница 3

DC Output protection fuse: 

If the charger does not initialize charging (Yellow LED2) and LED2 remains Green when connected to a known 
discharged battery, check the fuse under the twist cap. Use correct replacement fuse. Size: 5mmx 20mm, fast-
acting. Note the correct amperage of the fuse for the charge rate (amperage) charger model in use. 

  

Care of operation: 

-

 

Battery charger must only be used for the purpose specified by the manufacturer. 

-

 

Wear proper eye and clothing protection at all times 

-

 

Someone should be within range of your voice when working with a battery & charger 

-

 

Do not operate the battery charger if housing or cables are damaged. 

-

 

Lay cables in such a way they are not in risk of damage or tripping. 

-

 

Position charger on secure surface to avoid falling over, keep out of reach of children. 

-

 

Do Not smoke or exposed to spark or flame while charging 

-

 

Do not drop metal tools or personal items across battery terminals causing shorts or sparking 

-

 

A qualified person familiar with the risks involved must perform service or repair 

 

Caution!

  If you have any questions about proper charger application, contact Schauer 

Battery Chargers before connecting or attempting to operate charger.

 

 

 

 

CHARGING CURVE 

   

 

 

 

Schauer Battery Chargers                       

  

  

www.battery-chargers.com

                                                                             

3210 Wasson Rd., Cincinnati, OH 45209,  513-791-3030     

   

[email protected]

 

 