822.212 BA / EN

Instruction Manual

LR 1218 Solar Charge Regulator

Inhaltsverzeichnis

1

Safety Information

2

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

1.1

Meaning of safety symbols

2

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

1.2

General safety information

2

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

2

Introduction

3

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

3

Operation

3

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

4

System faults

3

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

5

Technical data

4

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

6

Application and functions in detail

4

. . . . . . . . . . . . . . . . . . . . . . . . .

7

Maintenance

4

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Appendix

5

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Содержание LR 1218

Страница 1: ...9577 29 www schaudt gmbh de 822 212 BA EN Instruction Manual LR 1218 Solar Charge Regulator Inhaltsverzeichnis 1 Safety Information 2 1 1 Meaning of safety symbols 2 1 2 General safety information 2 2 Introduction 3 3 Operation 3 4 System faults 3 5 Technical data 4 6 Application and functions in detail 4 7 Maintenance 4 Appendix 5 ...

Страница 2: ...faults which may impact personal safety or the safety of the device must be rectified immediately by qualified personnel Y DANGER 230V mains voltage carrying parts Danger of death due to electric shock or fire F Do not carry out maintenance or repair work on the device F If cables or the device housing are damaged no longer use the device and isolate from the power supply F Ensure that no liquids ...

Страница 3: ...ator with an Electrobloc see the instruction manual for the Electrobloc 3 Operation The solar charge regulator does not have any controls Y ATTENTION The output voltage of the charge regulator is not suitable for direct supply without battery Malfunction of or damage to connected consumers F Do not operate the solar charge regulator without a battery F Disconnect connector Plus Solar module s on t...

Страница 4: ...audt GmbH electroblocs with retrofit adapter for charging the starter battery 6 Application and functions in detail If the solar modules have sufficient charging voltage the solar charge regu lator allows the battery to be charged by up to 14 2 V As soon as these voltage is reached the charging current is reduced to fully charge the batteries without impairing them If the charging voltage of the s...

Страница 5: ...ference at any time Schaudt GmbH Elektrotechnik Apparatebau Planckstraße 8 88677 Markdorf Germany B Special fittings accessories IT 300 Solar instrument panel for direct connection to the batteries or to electroblocs with retrofit adapter C Customer service Schaudt GmbH Elektrotechnik Apparatebau Planckstraße 8 D 88677 Markdorf tel 49 7544 9577 16 e mail kundendienst schaudt gmbh de Office hours M...

Страница 6: ..._ Vehicle Manufacturer _______________________ Model _______________________ Own installation Yes No Upgrade Yes No Following fault has occurred please tick Battery is not charged when solar modules are connected Persistent fault Intermittent fault loose contact Other remarks E Design 1 2 3 Fig 1 LR 1218 Solar Charge Regulator 1 Solar module connection 2 Living area battery and starter battery con...

Страница 7: ... General safety information 2 2 Introduction 3 3 Scope of delivery 3 4 Mechanical installation 4 5 Electrical connection 5 5 1 Connections to living area battery and starter battery 5 5 2 Connection to an electrobloc EBL with DT LT 7 5 3 Connection to an electrobloc EBL with MNL 8 5 4 Block diagram connection diagram 9 6 Initial use 10 6 1 Checks prior to initial use 10 7 Technical data 10 7 1 Mec...

Страница 8: ...hould only be replaced once the system has been com pletely disconnected from the power supply F Only replace blown fuses once the cause of the fault has been identi fied and rectified F The rear of the device may become hot during operation Do not touch Y ATTENTION Voltage carrying parts Damage to devices F The electrical system of the motorhome or caravan must comply with current DIN VDE and ISO...

Страница 9: ...regulator F Connection set for the different applications F Instruction Manual F Installation instructions 1 2 3 4 5 6 7 8 9 10 11 12 Fig 1 LR 1218 Solar Charge Regulator Deliverables Pos Qty Name 1 1 LR 1218 solar charge regulator 2 2 Flat vehicle fuse 20A 3 1 Flat vehicle fuse 15 A 4 2 Fuse holder for flat vehicle fuse 5 5 Flat push on contacts 6 3 x 0 8 without sleeve 6 3 Screws 3 5 x 20 7 4 In...

Страница 10: ...ently ventilated place in the insula ted interior is to be selected for installation No condensation may be able to form on the device In order to prevent a build up of heat ventilation holes towards the living area must be provided in the upper and lower areas of the place of installation Its cross section is based on the size and average temperature of the place of installation Ensure a minimum ...

Страница 11: ... LT con trol and display panel F Connection to an EBL electrobloc with 3 pin MNL connection and adapter for starter battery 5 1 Connections to living area battery and starter battery Y ATTENTION Short circuits Damage to the solar charge regulator or fire damage to cable F To protect the supply lines in the event of a short circuit connect the fuses directly to the positive pole of battery Select t...

Страница 12: ...it diagram in Fig 2 Use the flat push on con tacts 6 3 x 0 8 without sleeve for this Fig 1 Pos 5 After crimping attach the insulating sleeves Fig 1 Pos 7 Insert the two fuses 2 First connect the connection cables for living area battery and starter battery to the solar charge regulator observing the polarity of the con nections Use the flat push on contacts 6 3 x 0 8 for this blue Fig 1 Pos 8 3 Co...

Страница 13: ...and display panel connector Y1 brown living area battery signal Y2 white starter battery signal G3 Solar module s LR 1218 Solar charge regulator The connection at the front of the solar charge regulator is established in the following sequence 1 Connect the electrobloc with cable X connection cable EBL charge currents for batteries Fig 1 Pos 11 2 Connect the electrobloc with cable Y signals for di...

Страница 14: ...ocs as of April 2008 can be used with the adapter F EBL 99 F EBL 100 F EBL 264 9 F EBL 240 F EBL 269 An IT 300 Solar display panel for the display of the solar charge current can be used as an optional extra For this application the follow parts are required from those delivered Pos Qty Name 1 1 LR 1218 solar charge regulator 2 3 1 20A or 15A flat vehicle fuse depending on EBL 3 1 Flat vehicle fus...

Страница 15: ...Y adapter cable EBL charge current for starter batteries Fig 1 Pos 10 F Ya to the vehicle side cable F Connect Yb on the electrobloc 3 Connect the electrobloc with cable X connection cable EBL charge current for caravan battery Fig 1 Pos 9 4 Fit the right flat vehicle fuse 15A or 20 A Fig 1 Pos 2 or 3 into the Solar fuse on the EBL Y The correct fuse rating is imprinted on the front plate of the E...

Страница 16: ...erating mode If the solar charge regulator is connected to an electrobloc ensure the battery cut off switch is enabled Connect the solar module to the solar charge regulator with the correct polarity The solar charge regulator is ready to use 7 Technical data 7 1 Mechanical data 56 x 75 x 110 H x W x D in mm including attachment feet 160 g Plastic black Aluminium powder coated gentian blue RAL 501...

Страница 17: ...max 19 A For example five solar modules each rated at 55W can be connected in pa rallel Per solar module U0 22 V Inominal 3 2 A Overall nominal current Inominal 16 A 7 3 Environmental parameters 20 C to 40 C 20 C to 70 C Operation in dry environment only 8 Storage Packaging Transportation Only transport and store the solar charge regulator if the packing is suitable and ambient conditions are dry ...

Страница 18: ...Installation instructions for solar charge regulator LR 1218 12 Date 22 09 2009 822 212 MA EN blank page ...