background image

Installation instructions electronic step control EMS 03-4

3

Date: 02.12.2016

8220319 MA / EN

+

--

Electronic

+12V (feed--in)

Motor

Motor

Negative battery

6

3

2

1
4

5

1

2
4

3

ST1

ST2

Drive in/lock [ST1--6] button

button

Minus for

Drive out/open [ST1--5] button

Drive out/open [ST1--2] button

Drive in/lock [ST1--3] button

[ST1--4]

[ST1--1]

Minus for

button

M

Motor control

EMS 03-4

Fuse

Fig. 2

Block diagram connection EMS 03-4

The polarity of the connections ”motor” is as follows:

Button in position

Connection ST2 - 1

Connection ST2 - 3

Drive in/lock

+

--

Drive out/open

--

+

5 Initial start up

5.1 Testing before initial start up

"

Ensure that the battery for the basic vehicle is properly connected.

5.2 Starting up

The step control is plug and play.

6 Technical data

6.1 Technical data

96 x 130 x 40 (D x W x H in mm), with plug and assembly bracket
180 g
Black plastic, assembly bracket: Steel plate, 1.5mm galvanised

6.2 Electrical data

for 12 V DC systems (10 to 14.5 V)
Stand-by current lower than 2,5 mA
EMS 03-4 can be used for step with following currents:

Operating current step:

approx. 3 A

Motor lock current step:

approx. 11 A

Switch off current EMS 03-4 :

7.5 A

±

10 %

If the motor is not switch off within 5 s via the current, it is automatically swit-

ched off by the time control function.

Before starting up

Dimensions

Weight

Housing

Operating voltage

Current consumption

Motor current

Содержание EMS 03-4

Страница 1: ...e step control and the battery voltage must also be connec ted The step control controls the motor in the following way F Driving the step control in an out by briefly tipping pressing the button at the entrance the motor is switched off when the step control re aches the stop F The motor stops if the step control meets an obstacle is jammed or frozen F The control can be accessed via an optional ...

Страница 2: ...in mm 1 Assembly bracket galvanised 2 Housing PA 4 Electrical connection Y WARNING Protection against reverse polarity Damaging the electrical equipment of the basic vehicle F Ensure that the necessary voltage levels for the control voltages cor respond with the necessary values F Only make connections if the system is not connected to a power sup ply Y ATTENTION Short circuits Damage to the step ...

Страница 3: ...re initial start up Ensure that the battery for the basic vehicle is properly connected 5 2 Starting up The step control is plug and play 6 Technical data 6 1 Technical data 96 x 130 x 40 D x W x H in mm with plug and assembly bracket 180 g Black plastic assembly bracket Steel plate 1 5mm galvanised 6 2 Electrical data for 12 V DC systems 10 to 14 5 V Stand by current lower than 2 5 mA EMS 03 4 ca...

Страница 4: ...e for reference at any time Schaudt GmbH Elektrotechnik Apparatebau Planckstrasse 8 88677 Markdorf Germany B Customer service Schaudt GmbH Elektrotechnik Apparatebau Planckstrasse 8 D 88677 Markdorf Tel 49 7544 9577 16 Email kundendienst schaudt gmbh de Office hours Mon to Thurs 08 00 12 00 13 00 16 00 Fri 08 00 12 00 Returning a defective device Always use well padded packaging Fill in and enclos...

Отзывы: