Instruction Manual EBL 101 D / EBL 101 C with OVP

7

Date: 29.04.2010

811.554 BA / EN

Fault

Remedy

Possible cause

Solar charger does not

work (power supply and

engine are off)

Solar panel in (partial)

shade or covered (snow or

dirt)

Move solar panel out of

shade or clean.

g

)

Solar charge regulator not Plug in solar charge regu-

Solar charge regulator not

plugged in

Plug in solar charge regu

lator

Defective fuse or wiring

Check fuse and wiring

Defective fuse or wiring

Check fuse and wiring

Solar charge regulator de-

fective

Check solar charge regu-

lator

12V supply does not work 12V main switch for the li-

12V main switch for the li-

12V supply does not work

in the living area

12V main switch for the li

ving area battery is swit-

12V main switch for the li

ving area battery must be

g

g

y

ched off

g

y

switched on

Activate battery isolation

on the DT

control and

Activate battery isolation

on the DT

control and

on the DT ... control and

switch panel

on the DT ... control and

switch panel

Defective fuse or wiring

Check fuse and wiring

Defective fuse or wiring

Check fuse and wiring

Defective Electroblock

Call customer service

The Electroblock cannot

be operated from the DT

Defective Electroblock

Call customer service

be operated from the DT

... control and switch pa-

nel

Y

The charging current is reduced automatically if the device becomes too

hot due to excessive ambient temperature or lack of ventilation. Always

prevent the device from overheating nevertheless.

Y

If the automatic shutdown mechanism of the battery monitor is triggered,

fully charge the living area battery.

3.4 Closing down the system

Y

ATTENTION!

Total discharge.
Damage to the living area battery:

F

Fully charge the living area battery before and after closing down the

system. Connect a vehicle with an 80 Ah battery and a vehicle with a

160 Ah battery to the mains for at least 12 and 24 hours respectively.

Y

ATTENTION!

Permitted input voltages exceeded.
Damage to connected consumers:

F

Do not operate any connected Schaudt solar charge regulator without

battery.

F

When the battery is changed or removed, first unplug the ”+ solar cell”

connector on the solar charge regulator.

Содержание EBL 101 C with OVP

Страница 1: ...BL 101 C with OVP Table of contents 1 Safety information 2 1 1 Meaning of safety symbols 2 1 2 General safety information 2 2 Introduction 3 3 Operation 3 3 1 Switching system on off 3 3 2 Changing the battery 4 3 3 Operating faults 6 3 4 Closing down the system 7 4 Application and functions in detail 8 4 1 Battery functions 10 4 2 Additional functions 11 4 3 Use as an exchange device 11 5 Mainten...

Страница 2: ... device must be rectified immediately by specialists Y DANGER Parts carrying 230V Risk of fatal injury due to electric shock or fire F Do not carry out maintenance or repair work on the device F If cables or the device housing are damaged do not use the device and isolate it from the power supply F Ensure that no liquids enter the device F The mains connection line may only be replaced by an autho...

Страница 3: ...ly use Initial settings are only required after the type of battery lead acid or lead gel has been changed or during commissioning or when upgrading with ac cessories see section 3 2 and EBL 101 D EBL 101 C with OVP installation instructions for details 3 1 Switching system on off Y ATTENTION Incorrect Electroblock settings Damage to connected devices Therefore prior to starting F Ensure the leisu...

Страница 4: ...nnected devices F Do not operate solar regulator without battery connected Y If an original Schaudt solar regulator is used the solar current can be dis played on the control and display panel e g DT For this the control and display panel must be configured accordingly a PIN is required Ask your dealer for advice 3 2 Changing the battery Y ATTENTION Use of incorrect battery types or incorrectly ra...

Страница 5: ... of the battery selector switch Damage to the battery F Move the battery selector switch to the correct position Disconnect the Electroblock from the mains before adjusting the battery selector switch Y When using AGM batteries moving the battery selector switch to the Lead Gel position is recommended Experience tells us that AGM batte ries are charged perfectly this way However suitability must b...

Страница 6: ...he vehicle g g p ration battery voltage constantly below 13 3 V Have the mains voltage constantly below 13 3 V Have the mains voltage checked Defective Electroblock Call customer service Living area battery is over charged during 230V ope ration battery voltage constantly above 14 5 V Defective Electroblock Call customer service Starter battery is not char No mains voltage Switch on the automatic ...

Страница 7: ...itch panel Defective fuse or wiring Check fuse and wiring Defective fuse or wiring Check fuse and wiring Defective Electroblock Call customer service The Electroblock cannot be operated from the DT Defective Electroblock Call customer service be operated from the DT control and switch pa nel Y The charging current is reduced automatically if the device becomes too hot due to excessive ambient temp...

Страница 8: ...witch is switched off Fully charge the living area battery before closing down the system Remove the solar cell connector on the solar charge regulator Remove the clamps from the battery terminals Y The battery alarm is no longer active Y The frost protection valve opens for certain heater systems when the li ving area battery is isolated from the Electroblock via the battery cut off The boiler an...

Страница 9: ...contains in addition F overvoltage protection OVP A DT control and switch panel must be connected for operation This de vice controls the electrical functions in the motorhome s living area as well as the accessories There are connections for an additional battery charger and a solar charge regulator Flat vehicle fuses protect the various circuits Exceptions here are the step and the frost protect...

Страница 10: ...discharge currents than for larger currents This provi des improved total discharge protection Monitoring is also performed in the switched off state A warning message is displayed below 12 0 V depen dent on current drain If the voltage of the living area battery sinks further falling below 10 5V the battery monitor immediately switches off all 12V consumers The control and display panel also swit...

Страница 11: ...on the solar charge regulator used either only the living area battery is charged or the living area battery and the starter battery 4 3 Use as an exchange device Electroblocks EBL 101 D and EBL 101 C with OVP can be used as ex change devices for the EBL 100 The plug and socket connections of the old device can all be used Some additional functions and plug connections of the EBL101 will however r...

Страница 12: ...y of equipment from February 26th 2008 Schaudt GmbH Elektrotechnik Apparatebau Daimlerstrasse 5 88677 Markdorf Germany B Special fittings accessories Schaudt DT switch panel required for operation Schaudt battery charger LAS with max 18 A charge current including suitable connection cable MNL Schaudt Solar charge regulator type LR or LRS required if the solar current is to be displayed for solar m...

Страница 13: ...mittent fault loose contact Other remarks E Technical details 230 V AC 10 47 to 63 Hz sinusoidal protection class I 1 9 A Depending on the control and switch panel approx 5 20 mA plus con sumption of controller electronics of refrigerator Measurement approx 10 minutes after disconnection from the mains F not connected to mains F 12 6 V battery voltage F Battery isolation not enabled F Control and ...

Страница 14: ...tomatic changeover to trickle charge with constant 13 8V In the trickle charge phase the voltage at the output of the charging module is constant Start of a new charging cycle by switching over to main charge if the battery voltage falls below 13 8 V for more than 5 seconds when loaded Start of charge also for totally discharged batteries The internal charge module can also be operated without liv...

Страница 15: ...nd switch panel 6 Connector DT control and switch panel 7 Connection block solar regulator measurement signal 8 Connection block reserve 9 Connection block solar regulator supply 10 Connection block additional charger 11 Connection block TV pump consumers 12 Selector switch acid gel battery 13 Self resetting step fuse internal 14 Flat vehicle fuses consumers 15 Battery cut off switch 16 AES refrig...

Страница 16: ...9to DT digital panel MNL bush socket 5F BL2 MNL bush socket 4F BL1 MNL bush socket 5F BL8 D point Signal solar living area battery Signal solar starter battery nc nc nc nc Refrigerator lines must be lead to the battery poles without being connected to other battery supplies every 1 5 mm2 max 10 m Compressor AES refrigerator Absorber refrigerator D point Negative refrigerator D point TV Pump Circui...

Отзывы: