13
Remote Control Pairing
1. To open the remote control, pull down the rear cover.
2. Press the P1 button once (or simply just power on the motor), the motor will beep 3 times.
3.
Within 10 seconds, press the left P2 button on the remote, the motor will have 1 beep and 1 jog. Press the P2 button again after the beep/jog, the
motor will again have 1 beep and 1 jog. Now press the UP or DOWN button, the motor will beep 3 times and jog 1 time, the remote is now paired
with the motor.
P2
P2
→
→
P2
P2
UP
DOWN
or
Switch the Motor Rotating Direction
After pairing the remote to the motor, if upon pressing the up down the motor travels downward (or vice versa), then the motor direction of travel will
need to be switched.
IMPORTANT:
This can only be done
before
the opening/closing limits have been taught in!! The motor will travel “limitless” until the limits have been
taught in and the rotating direction must be changed before setting the limits!!! If the travel limits have already been set, then the travel direction can
be changed either by deleting the travel limits (then switching the direction) OR via the P1 button on the motor (see above).
+
UP
DOWN
Press and hold the UP and DOWN buttons simulanteously for 2
seconds, the motor will beep 3 times and jog 1 time, the rotating
direction has been switched successfully.
Setting the Upper and Lower Limits
HINWEIS
•
Adjust the upper end position so that approx. 2-3 cm of the roller shutter protrude from the roller shutter box. Temperature differences in winter and
summer can cause material expansion, which can lead to tolerances.
• Check both end positions again before closing the roller shutter box again.
• Roller shutter motors are asynchronous motors and are not designed for continuous operation. If the operating time of 3-4 min. is exceeded, the
thermostat switch in the roller shutter motor switches off due to overheating. ATTENTION! The housing of the roller shutter motor can then become
hot! After approx. 20 minutes, the roller shutter motor has cooled down again and is ready for operation.
P2
→
→
P2
P2
P2
UP
1. Initiate the limit setting program
Press the P2 button on the remote (1 beep & 1 jog), press
UP (1 beep & 1 jog), press the P2 button again (3 beeps &
1 jog). The motor is to set the limits.
→
→
UP
STOP
STOP
Press UP, motor runs upward, press STOP once to stop
the motor in the desired position, press and hold STOP
for 5 seconds (3 beeps & 1 jog). The upper limit is set.
2. Setting the Upper Limit
→
→
DOWN
STOP
STOP
3. Setting the Lower Limit
Press DOWN, motor runs downward, press STOP once to
stop the motor in the desired position, press and hold
STOP for 5 seconds (3 beeps & 1 jog). The lower limit is set.
Adding a Preferred Position
P2
→
→
→
→
P2
DOWN
STOP
STOP
STOP
UP
or
1. Set preferred position (within the limits)
Assure that the upper and lower limits are set. Run the motor to the desired preferred position. Press
STOP once, then press P2 (1 beep and 1 jog), press STOP again (3 beeps and 1 jog), the preferred
position within the travel limits is set.