2.1.6
Compressed air connection
The SAB pressure regulator (see
) is connected to the Air cleaner module.
Figure 14:
Pressure regulator unit
2.1.7
Air cleaner module
Do always connect OMD to engine's control air system, pressure range 2 - 15bar. A
dry and clean (ISO8573-1:2010
–
6-4-4)
air with low humidity/oil
contamination is of high importance.
The Air cleaner module has an integrated float lever, when the filling level should
be too high, it will release the fluid automatically.
Figure 15:
Air cleaner module
Air cleaner
connection
Air outlet
Throttle block
Air filter
Fine pressure
regulator
Air flow
Air inlet
Pressure regulator
Air cleaner
module
Inside:
Filter Cartridge
273119