18
Procedure 3:
1.
Stop the engine and
reduce the incoming air
pressure
2.
Disconnect the RESET
task connector
3.
dismount the measuring
head
4.
disconnect the
connection case
5.
Change the small seal
(Part no.: 10206)
6.
Change the valve box seal
(Part no.: 10049)
7.
Reconnect the connection
case to the base plate
8.
unscrew the vibration
plate
9.
change the upper and
lower elastic mounting
system (Part no.: 10018 &
10019)
10.
change the flexible
bellows (Part no.: 10023)
11.
reinstall the vibration
plate to the base plate
12.
change the measuring
head seal (Part no.: 10022)
13.
reinstall the measuring
head at the vibration plate
14.
open the inspection
cover
15.
change the scavenging
air filter (Part no.: 10042)
16.
Change the seal for
inspection cover (Part no.:
10010/10166)
17.
clean the infrared
sensor glasses with cotton
sticks and alcohol (Part no.:
10036 & 10035)
18.
clean the bores with
cleaning needle (Part no.:
10135)
19.
change the screw plug
seal
¼” for inspection cover
(Part no.: 10082)
20.
close inspection cover
21.
unscrew the plugs at
the connection case
22.
change the screw plug
seal ½“ (Part no.: 10209)
23.
check the heating
element if it is hot. If cold
–
replace!
24.
Check all leaders in the
main socket. If bad
condition
– replace! (Part
no.: 10033)
Содержание VN 115/87 EMC
Страница 1: ...1 ...
Страница 13: ...13 Wire break resistance for VN 87plus Wire break resistance for VN 93 ...
Страница 40: ...40 ...