Installation, Mounting and Maintenance 

DISA-H

Содержание DISA-H Series

Страница 1: ...Ferdinand Schad KG Steigstra e 25 27 D 78600 Kolbingen Telefon 49 0 74 63 980 0 Telefax 49 0 74 63 980 200 info schako de www schako de Installation Mounting and Maintenance DISA H...

Страница 2: ...ormation 4 Identification of the delivered model 4 Function 4 Installation and commissioning 5 Operating conditions 5 Material reception 5 Transport lifting and handling 5 Storage 5 Installation 6 Mou...

Страница 3: ...acement of defec tive materials Recycling The inspection installation hydraulic connection and commissioning of the device must be carried out by qual ified skilled personnel only in compliance with t...

Страница 4: ...nsist of copper pipes 12 mm in thickness aluminium ribs diffuser system and a steel frame Grille 3 Louvre grid for supply air and return air optional Hydraulic connections 4 Upon customer request the...

Страница 5: ...tion it must be stored according to the following instructions Coolant or heating fluid water or glycols ethylene or pro pylene at a concentration below 60 Water inlet temperature above the dew point...

Страница 6: ...As standard the cooling circuit pipes are attached on the outside and the heating circuits at the centre of the register 4 pipe Hydraulic connections DISA H H 2 pipe Hydraulic connections DISA H HT 4...

Страница 7: ...rks During in stallation the manufacturer s specifications must be observed Temperature controls The temperature controls are mounted in accordance with the selected model This is why the instructions...

Страница 8: ...onnected to the hydraulic cir cuit with flexible hos es of sufficient length Hydraulic connections were tightened properly and exhib it no leaks Connecting and fastening elements have been sufficientl...

Страница 9: ...and the following formula can be used to to determine the volumetric flow V l s Primary air flow Ps Pa Static pressure The K value is taken from the following table Air density 1 2 kg m3 VZU m3 h supp...

Страница 10: ...r Install thermostat in a different place Clogging of the cooling heating register Clean the register in accordance with the maintenance instructions The unit is losing water Condensate in the registe...

Страница 11: ...100 SAFETY OF MACHINERY Safety of Machinery Basic terms general principles of design Part 1 Basic terminology methodology DIN EN ISO 12100 SAFETY OF MACHINERY Safety of Machinery Basic terms general p...