Schaffner Group
User and Installation Manual
Ecosine FS42842
15/43
8
Function diagram
Filter terminals
Line
3 touch safe terminal blocks (busbar terminals >240A)
Load
3 touch safe terminal blocks (busbar terminals >240A)
Disconnect
TDJ terminal 6 touch safe terminal blocks
Over-temperature NC switch, 250VAC/2.5A, touch safe terminal 4mm
2
contact
Open position indicates error
PE
Protective earth. Threaded studs with washer and nut
Function blocks
Chokes
Power magnetic components incl. over-temperature switch
Capacitors
Power capacitors incl. discharge resistors
Fan *
Field replaceable fan for choke cooling (some models)
Power supply *
Internally generated 24VDC for fan supply (some models)
* the following filters do not require forced cooling and therefore have no internal fan and power supply: FS42842 -
10, -13, -16