Power supply
Conditions
The electrical power supply must be connected in accordance with the applicable regulations (VDE 0100)
and the regulations of the country of installation. Type of power cable at least H05 RN-F. The voltage
specified on the serial plate must match the supply voltage at the installation location.
Danger of electric shock! the following instructions absolutely must be complied with:
● The phase must be fused at the ampere value specified on the serial plate.
●
It must be possible to disconnect the device from the mains power supply at all poles.
●
Never operate a device with a damaged power cord. Have a defective power cord or plug replaced
immediately by a qualified service technician.
●
Schaerer Ltd. recommends against using an extension cable. If, despite this, an extension cable
is used (minimum cross-section: 1.5 mm
2
), observe the manufacturer data for the cable (operating
instructions) and the locally applicable regulations.
●
The mains cables must be installed in such a way that they do not present a tripping hazard. Do not
pull the cords over corners or sharp edges, pinch them between objects or allow them to hang loose-
ly in a room. Do not place cables over hot objects, and protect them from oil and aggressive cleaning
products.
● Never lift or pull the device by the power cord. Never pull the plug out of the socket by its cord. Never
touch the power cord or plug with wet hands! Never insert a wet plug into a power socket.
Power requirements
Mains voltage tolerance
400 V (+10% / -10%), mains break < 50 ms no functional interruption
Protection
IP 50
Model
Power requirements
Fuse (installa-
tion site)
Connecting
cable conductor
cross-section
Europe normal
power
230 V AC
50/60 Hz
3000 W
1 x 16 A
3x 1.5 mm
2
Europe high
power
400 V AC
50/60 Hz
6000 W
3 x 16 A
5x 1.5 mm
2
Water connection/draining
Conditions
The water supply connection must be made in accordance with the applicable requirements and the regu-
lations of the respective country. If the machine is connected to a newly installed water line, the pipe and
the inlet hose must be thoroughly flushed to prevent particles from entering the machine. The coffee
machine must be connected to an installed drinking water line with a shut-off valve. The machine is con
-
nected to the pressure reducing valve on the main water valve (set to 0.3 MPa (3 bar)) using the mounted
pressure hose and the G 3/8" screw connection. If the machine is connected to a drain, the included tem-
perature-resistant drain hose must be connected to the drip tray and the siphon. It must be firmly attached
to the drain and slanted at a downward angle (so that the water can flow downward).
always use the new hose set (fresh water/outlet hose) provided with the machine! Do not use old
hose sets.
DangEr!
risk of electrocu-
tion!
CautIon!
risk of machine