Schaeffler Technologies
23
■
The sensor is suitable for a maximum temperature of 240ºC
(464°F).
■
In the event of temperatures exceeding 240ºC (464°F),
the connection between the magnet and the sensor is
interrupted. The heater switches off automatically when the
sensor does not detect a temperature increase.
■
Special clamp sensors are available for non-magnetic
workpieces.
■
Make sure that the sensor and workpiece surfaces are clean.
■
Always place sensor T1 on a flat area as close as possible
to the bore. Connect the sensor by inserting the plug into
the socket (in the casing). Make sure that the – and + of the
plug correspond to that of the socket. If desired, a second
sensor, T2, can be used for additional control or
monitoring of a temperature difference, ΔT, between 2
points on the workpiece.
7. The magnetic temperature sensor
■
2 Temperature sensors come with the heater and can be
reordered as spare parts.
■
The magnetic temperature sensor must always be used when
heating in one of the “temperature modes”.
■
The sensor can be used as a tool for temperature control
whilst heating in “time mode”.