WC-1/3HP Unit Description

The WayCool

®

evaporative cooler is a completely self-contained, portable unit capable of delivering 25.5 MPH velocity of air with a

temperature drop of up to 20°. The unit is composed of:

• Level-controlled water supply system
• Cooling pad assembly
• Motor-driven blower and ductwork
• Controls
• Frame and housing

The bottom is made of high impact ABS plastic and holds approximately 14 gallons at normal operating level (about 4" deep). 

A float-operated valve automatically maintains proper water level when the unit is connected to a water supply.

The bottom rests on, and is fixed to, an aluminum cradle. The bottom, in turn, is secured to the aluminum frame. Four casters (2 locking, 2
non-locking) are attached to the underside of the aluminum cradle.

A pump draws water from the bottom and discharges it through the vinyl hose to the PVC pipes located above the cooling pads. The PVC
pipes distribute water onto the top of the cooling pads; saturating them.  Excess water drips back into the bottom through the holes in the
cooling pad support channels.

The cellulose cooling pads sit in support channels and are held in place by plastic retaining grates. The grates also help prevent damage to
the cooling pads. Two pad sections fit in each side of the unit (total eight sections) to totally enclose the unit.

The blower is hung from the top of the frame and powered by a direct drive 1/3HP electric motor. The blower draws room air through the
cooling pads where it picks up moisture and cools by evaporation. The blower then discharges the cooled air.

Note: It is important the cooled space has sufficient air openings so the warmer air can flow out and be replaced by the cooled air.
A closed-in space or high humidity will reduce the cooling effect. See Unit Placement and Other Considerations in the "Operations
and Maintenance" section of this manual.

A screen covers the discharge duct to prevent foreign objects from entering the blower. A threaded rod screws through a threaded brace
above the screen to hold the blower duct in position. A plastic knob secures the blower duct to the rod. The blower duct is made of a tough,
durable plastic and can be manually rotated 360 degrees to provide cool air in any direction without moving the unit.

Note: Water weighs about eight pounds per gallon, so when the unit is full, it weighs over 240 pounds. During setup and before
startup, place the unit in the desired location and then fill the bottom.  Do not attempt to lift the unit once it is filled and be careful
to avoid spills when moving it; even over smooth ground. Do not try to push it over rough or soft ground as you can overstress
the wheels and frame and cause structural and component damage, which is not covered by warranty.

5

Содержание WayCool 1/3HP

Страница 1: ...Portable Evaporative Cooler WayCool 1 3HP Series USER S MANUAL...

Страница 2: ...3 Normal Startup 13 Normal Shutdown 13 TROUBLESHOOTING 14 Cooling Pads not Wetting 14 Foaming 14 Line Clogs or Obstructions 14 Splattering out Front 14 Leaking out Bottom 14 Odor Control 14 Scale Buil...

Страница 3: ...e cooling effect In an evaporative cooler the cellulose cooling pads take the place of your skin water instead of perspiration wets them and a fan moves the air The air blows across the cooling pads a...

Страница 4: ...the right to make changes at any time without notice Warning and Danger Decals have been placed on the equipment to warn of potentially dangerous situations Care should be taken to keep this informat...

Страница 5: ...nd wear gloves when you reach under the frame to inspect the PVC pipes and mesh socks A GFCI Ground Fault Circuit Interrupter is recommended for use with this product If pads and grates are removed fo...

Страница 6: ...e Pump Vane Type 210 GPH Gallons Per Hour Pump Filter Washable Polyethylene Filter Pump Discharge Filter 480 Micron Stainless Steel Reservoir Capacity 14 Gallons Optional Water Supply Standard Hose Co...

Страница 7: ...tal eight sections to totally enclose the unit The blower is hung from the top of the frame and powered by a direct drive 1 3HP electric motor The blower draws room air through the cooling pads where...

Страница 8: ...the bottom can also be manually filled with a hose or bucket if a hose connection is impractical Simply remove any of the plastic retaining grates and one of the cooling pad sections and place the ho...

Страница 9: ...r flow to the cooling pads is reduced and performance decreases The clear filter housing is threaded and screws into the filter body for easy removal to access the screen Note A dirty water supply wil...

Страница 10: ...when wet Always run the unit with the plastic retaining grates in place and handle them carefully when you clean them Crushed cells reduce the total airflow through the unit and therefore lowers it s...

Страница 11: ...bare connections or you could be injured The power cord runs down the frame leg that has the control switch on the outside It exits the frame leg at the bottom and has a male plug that must be plugge...

Страница 12: ...the pump is OFF Use this setting to quickly dry the cooling pads for removal and cleaning LOW COOL The blower runs at low speed and the pump is on Use this setting for low cooling loads HIGH COOL The...

Страница 13: ...he air flowing in the same direction Do not direct other fans against the WayCool unit It will counter the WayCool s airflow and stop the cooling effect Obstructing the airflow from the WayCool unit s...

Страница 14: ...bottom 6 Remove the cooling pads from all four sides of the unit Place a putty knife or large flat bladed screwdriver under the pad to lift it up then outward With one pad out the rest can be easily r...

Страница 15: ...nce it is filled Damage to the unit or a large spill may occur Note When you decide where to place the unit make sure there are no obstructions in the way that will disrupt or block the airflow Make s...

Страница 16: ...t hold on the unit s top cover 5 Remove the top cover and set it aside 6 Locate the four PVC pipes in the top metal channel Each PVC pipe is secured to the Y connector by a single screw Remove this sc...

Страница 17: ...he pneumatic wheel options includes two locking and two non locking wheels Pneumatic wheels are designed to allow for easy rolling on rough or uneven surfaces 15 WayCool Water Condition is recommended...

Страница 18: ...eed to be replaced 5 If the motor is not running the motor may have failed or there could be a wiring problem contact a certified electrician If the motor is determined to have failed it must be repla...

Страница 19: ...umper labeled A into the L position on the switch 15 Cut the black wire from the power cord just below the blue connector and then strip of plastic from the black wire 16 Twist the bare end of this wi...

Страница 20: ...arts To order replacement parts contact the dealer from whom you purchased your WayCool If you do not have that information please call Schaefer Ventilation Equipment at 800 779 3267 to locate a deale...

Страница 21: ...rranty THERE IS NO WARRANTY OF MERCHANTABILITY AND THERE ARE NO WARRANTIES WHICH EXTEND BEYOND THE DESCRIPTION OF THE FACE HEREOF Products with warranty periods that exceed our standard one year warra...

Отзывы: