6

Set-Up / Operation (continued)

To prepare models PVM18LC and PVM18 for
operation:

1.

Place 

empty

cooler/tank in approximate location to be

misted. Carrying a full cooler/tank will be difficult as
it will weigh approximately 80 pounds.

2.

Fill cooler/tank with water (and ice, if desired).

3.

Place the fan/pump enclosure on the cooler/tank.

4.

Be sure the intake line and filter are in the bottom of
the cooler/tank.

5.

Fasten the straps to the handles on both sides of the
tank.

* Model PVM18LC does not include a tank. Since the
pump enclosure is specifically made to fit a 10 gallon Igloo
cooler, it must be used only with this type of cooler,
supplied by the user. 

DO NOT USE THE PVM18LC

WITH ANY OTHER WATER RESERVOIR!

WARNING

TIP HAZARD

• Serious injury is possible.
• Support weight of fan with free hand when

moving cart.

• Do not fill tank before moving cart.

To prepare model PVM18C for operation:

1.

Assemble cart as described earlier.

2.

DO NOT FILL TANK BEFORE MOVING CART.

Water in tank will add extra weight (about 80 pounds)
and is likely to spill out when cart is tilted back. This
can also make the cart unstable and hazardous to
move.

3.

Carefully move assembled cart to desired location.

4.

Remove the pump enclosure and fill tank with water
(and ice, if desired). Replace the pump enclosure on
the tank. Be sure the intake line and filter are in the
bottom of the tank.

5.

Fasten the straps to the handles on both sides of the
tank.

• Never operate pump without water supply.
• If leaks are observed, turn pump off and tighten fittings by hand.
• Excessively hard water (high solids) can plug nozzles.
• A plugged filter caused by poor water quality can restrict flow to pump and cause permanent damage.
• Never allow "fog" from the nozzles to come in contact with surfaces. This can cause condensation and water will form

on those surfaces; redirect the fan to prevent this circumstance.

CAUTION

Intake line

Filter

actoolsupply.com

actoolsupply.com

Содержание VersaMist PVM18 Series

Страница 1: ...N INSIDE PVM18 Read understand and follow all safety information and instructions in this manual before using or servicing this product Serious injury or death is possible Retain these instructions fo...

Страница 2: ...saMist PVM18C Portable Misting Fan Schaefer VersaMist PVM18LC B Portable Misting Fan Schaefer VersaMist PVM18LC Portable Misting Fan Schaefer VersaMist PVM18 B Portable Misting Fan Schaefer VersaMist...

Страница 3: ...apidly evaporated The heat required to evaporate the fog is extracted from the air causing a reduced air temperature This cooler air is then distributed to people or animals creating a direct cooling...

Страница 4: ...fault circuit interruptor GFCI is attached to the power cord Equipped with a power cutoff tip switch Includes one extra nozzle and two plugs A 10 gallon tank is included for use as water reservoir Sh...

Страница 5: ...all four bolts are in Tighten the four flange locks on the four bolts STEP 2 PLACE TANK ON CART STEP 3 REMOVE BOLT FROM POST TOOLS REQUIRED One 9 16 wrench Remove the bolt lock washer and washer from...

Страница 6: ...gs provided 7 The unit will mist for approximately five hours on 10 gallons of water GFCI TEST The ground fault circuit interruptor GFCI mentioned above provides protection from electric shock by exam...

Страница 7: ...odel PVM18C for operation 1 Assemble cart as described earlier 2 DO NOT FILL TANK BEFORE MOVING CART Water in tank will add extra weight about 80 pounds and is likely to spill out when cart is tilted...

Страница 8: ...ater conditions The filter should be inspected frequently and changed as needed A dirty filter will restrict water flow to the pump and can cause permanent damage SYSTEM DRAIN STORAGE When it is time...

Страница 9: ...oper operation or lack of appropriate or regular maintenance of the product b Loss of time inconvenience loss of use of the product or other consequential or incidental damages c Parts that need repla...