background image

7

Heater Elements

Notes:

All heaters have a ground wire attached to the heater shell (not the element).

Alternate connections for dual service elements are under "Alternate Schematic".

Schematics with an asterisk (A*, B*) connect to a common hot wire (H), not a neutral wire (N).

Schematics with an apostrophe (B') require the neutral wire (N) to be capped.

Heater elements and wiring schematics that allow high/low staging are shaded.

(1) Voltage between hot and neutral is 120V.
(2) Voltage between hot and neutral is 277V.

Power

No. of

No. of

Voltage

Alt.

Voltage

Element

Heater

(W)

Stages

Wires

Schem. (V)

Schem. (V)

7501

HZRE15120C

HZS15120

1500

1

2

A

120

7503

HZRE15208C

HZS15208

1500

1

2

A*

208

7504

HZRE15240C

HZS15240

1500

1

2

A*

240

7505

HZRE15277C

HZS15277

1500

1

2

A

277

75301

HZRE30120/240C

HZS30120/240

3000

2

3

B

120

B'

240

75302

HZRE30208C

HZS30208

3000

2

3

B*

208

75303

HZRE30208YC

HZS30208Y

3000

3

4

C

208 (1)

75304

HZRE30208DC

HZS30208D

3000

3

3

D

208

75305

HZRE30240/480C

HZS30240/480

3000

2

3

B*

240

B'

480

75309

HZRE30480C

HZS30480

3000

1

2

A*

480

75501

HZRE50120C

HZS50120

5000

3

4

C

120

75502

HZRE50208SC

HZS50208

5000

2

3

B*

208

75503

HZRE50208YC

HZS50208Y

5000

3

4

C

208 (1)

75504

HZRE50208DC

HZS50208D

5000

3

3

D

208

75505

HZRE50240/480C

HZS50240/480

5000

2

3

B*

240

B'

480

75507

HZRE50277C

HZS50277

5000

2

3

B

277

75508

HZRE50346C

HZS50346

5000

1

2

A

346

75510

HZRE50480YC

HZS50480Y

5000

3

4

C

480 (2)

75511

HZRE50600C

HZS50600

5000

1

2

A*

600

Содержание HotZone Patio Heater

Страница 1: ...n com www schaeferfan com High Output Infrared Heater 1500 3000 Watt INSTALLATION OPERATION INSTRUCTIONS 3019762 HotZone Portable Heater HotZone Wall Mount Heater HotZone Patio Heater HotZone Universal Fixed Mount Heater HOTZONE HEATERS MUST BE INSTALLED BY A LICENSED ELECTRICIAN ...

Страница 2: ...er as a kind of floodlight and place it so as to cover your target area with enough heat The temperature increase resulting from the heater shining on a target depends on the power of the heater the distance from the heater to the target and how close the target is to the center of the spot DO NOT allow the heater to be aimed at a wall or any other combustible material The heater unit with fixed m...

Страница 3: ... to properly grounded outlet only The heater should always be connected to a grounded circuit If a GFCI socket is not available GFCI adapters can be purchased locally Heater must be installed according to NEC and all local electrical codes Be sure the electrical supply is adequate for the heater voltage amps phase while allowing for line losses Use supply wires suitable for 90 C 10 Do not insert o...

Страница 4: ...e assembly and allow the heater to be aimed as desired Typically the assembly should be in the middle of the back of the heater for downward facing ceiling mounting and toward the bottom and forward on the heater for downward through horizontal facing wall mounting see page 5 Be sure you are supplying the correct voltage to the heater allowing for line losses The heater s voltage requirements are ...

Страница 5: ... Save all hardware for re use 1 Remove the two cap screws from the back of the heater which are holding the louvered element tray in place 2 Slide the element tray out of the heater Pull the high temperature element wires through the hole in the angle adjustment assembly to free the element 3 Remove the two allen screws that attach one end of the curved mounting plate to the heater 4 Remove the tw...

Страница 6: ...range white and heats up very quickly The heater is receiving too much power and will burn out very quickly if it is not turned off Is the heater wired correctly for its element type Is the element damaged A short circuit between adjacent coils will cause some coils to go dark and some coils to overheat Damaged elements cannot be repaired and must be replaced MAINTENANCE The heater body can be was...

Страница 7: ...500 1 2 A 120 7503 HZRE15208C HZS15208 1500 1 2 A 208 7504 HZRE15240C HZS15240 1500 1 2 A 240 7505 HZRE15277C HZS15277 1500 1 2 A 277 75301 HZRE30120 240C HZS30120 240 3000 2 3 B 120 B 240 75302 HZRE30208C HZS30208 3000 2 3 B 208 75303 HZRE30208YC HZS30208Y 3000 3 4 C 208 1 75304 HZRE30208DC HZS30208D 3000 3 3 D 208 75305 HZRE30240 480C HZS30240 480 3000 2 3 B 240 B 480 75309 HZRE30480C HZS30480 3...

Страница 8: ...ion and or replacement of the heater element 1 Turn off power supply to the heater 2 Carefully remove the heater from the mount and disconnect the power supply The original white high temperature lead wires should be coming out through the mounting stub Figure 6 Be sure to save all hardware for re use 3 Place the heater on a level flat surface Be careful not to bend the lens lay the heater on a so...

Страница 9: ...ure lead wires using the hardware that was removed from the used element Follow the appropriate wiring schematic on page 7 Figure 9 12 Carefully slide the element frame back into the heater The lead wires must be carefully pulled back through the mounting stub as the element is slid into place leaving them loose in the heater housing can cause them to overheat Figure 6 13 Replace the two allen scr...

Страница 10: ...s to reverse the angle adjustment assembly before continuing 3 Thread the lead wires from the heater through the appropriate tube provided choose the 8 tube for ceiling mount 4 tube for wall mount and then through the stub in the cover plate 4 Secure the tube to the heater stub with a trilobal screw provided Secure the tube to the cover plate stub with the remaining trilobal screw 5 Recruit an ass...

Страница 11: ...ropriate or regular maintenance of the product b Loss of time inconvenience loss of use of the product or other consequential or incidental damages c Parts that need replacement due to normal wear and tear d Superficial or cosmetic rust or corrosion e Any product whose name plate has been removed Products with warranty periods that differ from the standard 2 year warranty are as follows Poly Housi...

Страница 12: ...800 779 3267 www schaeferfan com 2010 Schaefer Ventilation Equipment 11 17 10 ...

Отзывы: