Introduction
The Algarve patio heater produces heat like the sun, warming people and objects and not the air in between,
providing the only form of heat that will not blow away. The Algarve is primarily designed for outdoor use and
it is therefore weatherproof (IP54 rated) and UL Listed.
Please read the following instructions carefully before use. The safety of this heater is guaranteed
only by its correct usage in accordance with these instructions, therefore it is recommended that
they are retained for future reference.
Caution!
Before using this appliance:
• Check that the voltage indicated on the type plate corresponds to the main supply voltage.
• Ensure that the heater has been securely fastened to the mounting.
• Disconnect main power during installation, cleaning and/or emitter replacement and ensure that the
emitter is cool.
• Do not handle the halogen emitter with bare hands. If it is advertently
touched, remove finger marks with a soft cloth and methylated spirit or
alcohol, otherwise the marks will burn into the quartz, causing
premature heater failure.
• Touch the front glass as little as possible in order to avoid unslightly grease
residue.
• Do not use an extension cable with this product.
• Keep the main cable away from the body of the heater which will get hot
during use.
• Do not cover or obstruct the heater when in use.
• Ensure that children do not tamper with the heater.
• Do not insert any object into the heater.
• Do not use if glass is broken.
Risk of Fire
Keep combustible materials such as furniture, papers, clothes and curtains
at least 3 feet
from the front of
the heater and away from the sides and back. If the heater is to be used outside, a weatherproof outlet is
recommended.
Specification - Table 1
Installation Instructions
Wiring
• Warning - this heater must be grounded.
• The wired versions (212/US) are fitted with a 16'5" power
cord with a molded plug, therefore it is unnecessary to
remove the terminal box cover in order to carry out normal
installation of these models.
• All installations must be in accordance with the I.E.E. safety
regulations or equivalent.
• All unwired version should be installed by a suitably qualified
electrician, following the instruction below.
• When the electrical connection is outside, it is recommended
that a waterproof socket is used for the
connection/termination.
• If in any doubt, please contact a suitably qualified electrician.
1. Unscrew the terminal box cover at the back of the heater
and feed the supply cable through the compression fitting.
2. Use a heat resistant supply wiring with ground. The live and
neutral wires must be covered with the protective silicon
casings provided before connecting them to the terminal
block. See Fig. 1.
3. The green/yellow wire should be connected to the clamp
marked with the ground symbol.
4. Tighten the barrel nut of the compression fitting so the
rubber seal grips the cable. The seal can be adjusted to
accommodate cables of approx. 3/8" diameter. See Fig. 2
5. Replace the terminal box cover and tighten the screws.
6. Ensure that the cover is secured well to prevent water
ingress.
Mounting
• Allow the heater to cool before attempting to reposition/
move. Never attempt to move the heater with it switched on!
• The heater must be mounted in such a way that the halogen
emitter does not slant more than 4" from the horizontal.
• Observe the minimum safe distance between the heater
body and inflammable surfaces when mounting.
• Please refer to Table 1 for the recommended positioning of
the heater.
• Keep out of the reach of children.
1. Securely fasten the bracket to the mounting surface using
the fixing holes in the mounting bracket. The torque of the
bracket fastening crews must be at least 8 Nm.
2. Securely fasten the heater on the bracket using the nut and
bolt supplied. See Fig. 1 and Fig. 2.
Part No.
ALG-212
Voltage (V)
120
Total Power (kW)
1.2
Amps (A)
10
Minimum mounting height from floor
8'2"
Minimum distance from ceiling
1'7 5/8"
Minimum distance from side wall
4'11"
Dimensions W x H x D
15 3/4" x 7" x 5 3/4"
Weight
4.5 lb.
Insulation Class
1
Lampholder
R7S
Ingress Protection
IP54
*All measurements are approximate and can be subject to change without prior notification.
Minumum mounting height
Fig. 1
Fig. 2
Fig. 1
Fig. 2
9'10"
1' 7
5
/
8
"
Max 50°
96 feet
2
3"
9'10"
9'10"
8'2"