SCENTROID Scentinal SL50 Скачать руководство пользователя страница 6

www.scentroid.com

 

Page

 

|

 

5

 

  

Product

 

Name

 

Scentinal

 

SL50

 

Maximum

 

#

 

of

 

Sensors

 

20

 

Type

 

of

 

sensors

 

PID,

 

NDIR,

 

EC,

 

Laser

 

Particulate

 

counter,

 

and

 

MOS

  

Sampling

 

rate

 

Adjustable

 

from

 

0.5

 

to

 

999

 

min

  

#

 

of

 

Sampling

 

ports

 

1

 

to

 

3

 

Weight

 

77 LB

 

Size

 

24"

 

x

 

20"

 

x

 

8"

 

Power

 

requirements

 

100

240V

 

50/60HZ

 

2A

  

Power

 

Consumption

 

30W

 

without

 

AC

   ‐    

150W

 

with

 

AC

 

Communication

  

GPRS

 

(Default),

 

LAN

 

(Default),

 

WIFI

 

(optional)

 

On

Board

 

Data

 

storage

 

64GB

 ‐ 

SD

 

Card

 

Cloud

 

Server

 

Included

 

by

 

Default

 

Local

 

Server

 

Optional

 

On

Board

 

Server

 

Included

 

by

 

Default

   

User

 

Interface

 

7”

 

touch

 

screen

 

on

 

Panel

 

door

 

and

 

Remote

 

access

 

Sensor

 

Information

 

Management

 

System

 

Ambient

 

Temperature

 

range

 

0

 

to

 

35

 

°C

 

without

 

AC

 

system

 

50

 

to

 

+50

 

°C

 

with

 

Heating

 

and

 

AC

 

system

 

Sample

 

conditions

 

50

 

to

 

+50°C

 

and

 

10

 

 

90%

 

RH

 

without

 

pre

dilution

 

system

 

50

 

to

 

120°C

 

and

 

0

 

 

100%

 

RH

 

with

 

pre

dilution

 

system

 

Decontamination

  

Automated

 

procedure

 

using

 

oxidization

 

technology

 

Calibration

 

Manual

 

using

 

calibration

 

gas

 

and

 

On

board

 

screen

 

Optional

 

automatic

 

calibration

 

using

 

built

 

in

 

calibration

 

gas

 

Warranty

 

24

 

Months

 

full

 

warranty

 

on

 

all

 

parts

 

including

 

sensors

 

Sensor

 

replacement

 

frequency

 

Sensor

 

dependant

 

 

first

 

2

 

years

 

covered

 

by

 

warranty

 

Software

 

Sensor

 

Information

 

management

 

System

 

 

free

 

access

 

for

 

life

 

of

 

product

 

Cabinet

 

NEMA

 

4X

 

Mounting

 

hardware

 

Wall

 

and

 

pole

 

mounting

 

hardware

 

included

 

1.5

 

Scentinal

 

Specifications

 

(ES) Equipements Scientifiques SA - Département 

Bio-tests & Industries 

- 127 rue de Buzenval BP 26 - 92380 Garches

Tél. 01 47 95 99 

90

 - Fax. 01 47 01 16 22 - e-mail: 

bio

@es-france.com - Site Web: www.es-france.com

Содержание Scentinal SL50

Страница 1: ...ES Equipements Scientifiques SA D partement Bio tests Industries 127 rue de Buzenval BP 26 92380 Garches T l 01 47 95 99 90 Fax 01 47 01 16 22 e mail bio es france com Site Web www es france com...

Страница 2: ...TOMS 23 6 Scentinal Accessories 25 7 Scentinal Application Industries and Recommended Sensors 26 8 Installation Maintenance and Operation Cost 31 9 After Sale Support 34 10 Scentinal 35 ES Equipements...

Страница 3: ...not only store and display monitoring results but also provide remote configuration calibration and diagnosis of multiple Scentinal units Scentinal is a simultaneous ambient pollutant and odour emiss...

Страница 4: ...er Scentinal is equipped with up to three optional programmable relays that can be used to activate alarms mitigation technology and any other electrical device based on monitored parameters For examp...

Страница 5: ...lectricity and GPRS data GPRS costs are less than 100 per year Add to that Scentroid s unparalleled 2 year comprehensive warranty covering all aspects of the instrument including even sensors and Scen...

Страница 6: ...50 C with Heating and AC system Sample conditions 50 to 50 C and 10 90 RH without pre dilution system 50 to 120 C and 0 100 RH with pre dilution system Decontamination Automated procedure using oxidiz...

Страница 7: ...instrument and provide real time diagnostics The Scentinal on device server is capable of storing data locally for up to 5 years This data can be polled by the central station as required and if the s...

Страница 8: ...oid com Page 7 ES Equipements Scientifiques SA D partement Bio tests Industries 127 rue de Buzenval BP 26 92380 Garches T l 01 47 95 99 90 Fax 01 47 01 16 22 e mail bio es france com Site Web www es f...

Страница 9: ...ne pollutants levels exceed limits 3 Secondary polishing filter only when needed to reduce operating costs 4 Activate external sampling pump for bag sampling The limits and conditions for engagement o...

Страница 10: ...the contamination has been dealt with This means that once installed Scentinal is virtually maintenance free 2 5 Flexible Sensing and Modular Design The Scentinal product can be equipped with up to 20...

Страница 11: ...FI LAN Analog SCADA The system can either connect to a local server or Scentroid s cloud based SIMS server Cloud based SIMS server is included and free for the life of the Scentinal It is even possibl...

Страница 12: ...sport and install Scentinal weighs just 10 Kg and can be setup in a matter of minutes Easy to use Portable Quick to setup ES Equipements Scientifiques SA D partement Bio tests Industries 127 rue de Bu...

Страница 13: ...pling hoods or be directly connected to a PTFE line 2 10 Noise Monitoring In addition to gas and particulate monitoring Scentinal can also be equipped with outdoor Class 1 noise sensor No additional e...

Страница 14: ...nsing system is to input the data into Scentroid s real time dispersion modeling software TOMS TOMS offers a complete integrated suite for odour management The system provides a perfect integration of...

Страница 15: ...tinal can also be setup to provide localized visual and audible alarms The user can remotely configure each Scentinal providing it with the desired sampling rate transmission rate purging frequency an...

Страница 16: ...2 14 Scentinal Sensor List Type ES Equipements Scientifiques SA D partement Bio tests Industries 127 rue de Buzenval BP 26 92380 Garches T l 01 47 95 99 90 Fax 01 47 01 16 22 e mail bio es france com...

Страница 17: ...com Page 16 Type ES Equipements Scientifiques SA D partement Bio tests Industries 127 rue de Buzenval BP 26 92380 Garches T l 01 47 95 99 90 Fax 01 47 01 16 22 e mail bio es france com Site Web www e...

Страница 18: ...m and set all parameters The monitoring station is designed to collect all data from the sensors and present the sensor data in an easy to understand graphical interface 3 2 Local Server Optional It i...

Страница 19: ...og SCADA Scentinal is an open platform allowing interface to many other instruments and systems such as the plant SCADA Scentinal can be setup to transmit any one of the sensor outputs as 0 5V or 4 20...

Страница 20: ...oid com Page 19 ES Equipements Scientifiques SA D partement Bio tests Industries 127 rue de Buzenval BP 26 92380 Garches T l 01 47 95 99 90 Fax 01 47 01 16 22 e mail bio es france com Site Web www es...

Страница 21: ...Configuration SIMS Equipment Setting ES Equipements Scientifiques SA D partement Bio tests Industries 127 rue de Buzenval BP 26 92380 Garches T l 01 47 95 99 90 Fax 01 47 01 16 22 e mail bio es france...

Страница 22: ...e inputted into the learning algorithm along with recorded chemical composition This sophisticated algorithm will then create a non linear relationship between chemical readings and odour concentratio...

Страница 23: ...These sensors allow Scentinal to get individual pollutant levels Sensors are selected based on the application and therefore customized to individual plants This allows Scentinal to find the real trac...

Страница 24: ...lly logged and compared to odour emissions for fast and efficient validation 5 2 Real Time Odour Dispersion Monitoring Total Odour Management System uses AERMOD dispersion modeling current weather dat...

Страница 25: ...generation Uses USEPA approved AERMOD modeling Can be used to monitor individual compounds or total odour impact Cloud based solution with 100 data reliability 2 way communication to residents and en...

Страница 26: ...wer consumption and ensure Scentinal can operate in any ambient temperature from 50 C to 50 C 6 2 Scentinal Solar Power Unit For locations where getting power to Scentinal might be challenging a 300W...

Страница 27: ...de Low Concentration Particulate PM 1 2 5 10 Simultaneous Environmental odour is the highest source of nuisance and generates the greatest complaints Environmental odour can be generated from a variet...

Страница 28: ...ous monitoring of all important parameters such as CO2 CO O2 PM1 10 as well as pollutants such as H2S Formaldehyde SO2 VOC and Odour The system can be programmed to activate mitigation technology or c...

Страница 29: ...Chloride Hydrogen Cyanide Ammonia Oxidizing Gases Ozone and Nitrogen Dioxide Phosphine Low Concentration Phosphine High Concentration Hydrogen Sulfide Low Concentration ppb Organic Solvents Ethanol I...

Страница 30: ...r quality to prevent any prolem for the worker they need to make sure the work place is safe for everybody Recommended Sensors are Carbon Dioxide High Concentration Carbon Monoxide High Concentration...

Страница 31: ...ore Sl50 will also calculate efficacy of activate carbon send alarm for replacement For example SL50 can detect if odour after bio filter is above emission limit to engage carbon filter By using activ...

Страница 32: ...mount it to a wall or a pole and plug in the AC power Solar panels and rechargeable battery option allows the unit to work in remote locations Once powered the instrument will determine its location u...

Страница 33: ...en and using calibration gas Calibration should be done at minimum every year to ensure optimal performance The entire calibration does not take more than 10 minutes per sensor and requires minimal te...

Страница 34: ...t is dependent on the country of installation for example Australia Canada UAE UK and USA is roughly 100 per year 0 25 per MB rate and 2 minute update time is assumed Sensors are warrantied for 24 mon...

Страница 35: ...scentroid com 9 1 Training Training is the key of using any instrument and Scentroid provides worldwide training programs for our clients and distributors Training can be conducted by Scentorid or yo...

Страница 36: ...s you select PID NDIR Fuel Cell Laser Scattered Metal Oxide sensors therefore you never pay for more than what you need At Scentroid we pride ourselves on our customer care and after sales support We...

Страница 37: ...ioxide 0 10 ppm 0 29 g m3 0 009 ppm 25 g m3 0 14ppm 24h 365 g m3 0 133 ppm 1h 0 047 ppm 24h 350 g m3 1h 125 g m3 24h Carbon Monoxide 0 25 PPM 0 29 g m3 0 04 ppm 0 05 g m3 9 ppm 88h 10 3 g m3 8 74 ppm...

Страница 38: ...oid com Page 37 ES Equipements Scientifiques SA D partement Bio tests Industries 127 rue de Buzenval BP 26 92380 Garches T l 01 47 95 99 90 Fax 01 47 01 16 22 e mail bio es france com Site Web www es...

Страница 39: ...am ON L3R 4C1 Contact us 1 416 479 0078 Web and Email Email info scentroid com www scentroid com ES Equipements Scientifiques SA D partement Bio tests Industries 127 rue de Buzenval BP 26 92380 Garche...

Отзывы: