![Scantronic 9448+ Скачать руководство пользователя страница 19](http://html.mh-extra.com/html/scantronic/9448/9448_installation-and-programming-manual_1207049019.webp)
496236 Issue 4
17
Detector Circuit Connections
The right hand edge of the main PCB provides a connector for the six zones
and the Entry/Exit Zone, see Figure 12. Each zone (circuit) should have an
Anti-Tamper circuit associated with it. Link all the zone anti-tamper circuits in
series and then connect them to the A/T terminals on the main PCB.
Figure 12. Detector Circuit Connections
Connecting Door Contacts
Figure 13 shows the connections for one door contact per zone loop. Use
four core cable for the tamper and circuit connections. Note that the reed
switch inside the door contact is connected to the plated screws (shown in
black in Figures 8 and 9).
Figure 13. Connecting One Door Contact per Zone
3. Installation
Содержание 9448+
Страница 1: ......