6.1 Replacement of motor brushes
For the COMPACT 36 drill, the state of the carbon brushes should be
monitored every 100 working hours.
Replacement of motor brushes should be carried out when the machine
is switched off and with the power cord unplugged from the power socket!
.
1
2
3
4
5
6
3
4
5
6
1. Loosen 4 4x19 screws (1), fastening the motor cover (2).
2. Remove the motor cover (2).
3. Loosen 3x13 screws (3), fastening the pressure plate (4) of the brush holder
(5).
4. Remove the brush holder pressure plate (4).
5. Be careful not to remove the brush conduit, lightly raise the brush holder (5)
and remove the motor brush (6).
6. Monitor brush length - If the length is less than 5 mm, it must be exchanged
for a new brush.
7. Carry out all actions in reverse, in order to install the motor.
Caution:
During the installation of the brush-holder (5), pay attention to the
placement of conductors under the brush-holder - they must be placed in a special
recess made in the motor housing.
After replacement of new brushes, they must be ground in for about 20 minutes
on the idle gear. Replacement of motor brushes is possible without removing the
drive from the drill.