Squelch Delay #2 in Search Mode
Stalk(Sweep)SrchSQ1
Length of time to wait for a signal on a frequency during Stalker/Sweeper while
searching
(small signal quality).
Default Value 10
(10 ms).
Values:
Enter
1-100
(1 - 100 ms).
Menu Help Text:
Stalker/Sweeper search small sig qual
Win500 Name
Extended Settings>Spectrum Sweeper>
Narrow SQ timeout 1
PSREdit Name
- Weather/Advanced Configuration>Sweeper/Search
Options>
Squelch Delay #1 in Search Mode
Stalk(Sweep)AMDelay
Length of time to wait to unmute in AM mode during Stalker/Sweeper.
Default Value 150
(150 ms).
Values:
Enter
1-255
(1 - 255 ms).
Menu Help Text:
Stalker/Sweeper unmute delay - AM mode
Win500 Name
Extended Settings>Spectrum Sweeper>
AM unmute delay
PSREdit Name
- Weather/Advanced Configuration>Sweeper/Search
Options>
Unmute Delay (AM Mode)
Stalk(Sweep)FMDelay
Length of time to wait to unmute in FM mode during Stalker/Sweeper.
Default Value 50
(50 ms).
Values:
Enter
1-255
(1 - 255 ms).
Menu Help Text:
Stalker/Sweeper unmute delay - FM mode
Win500 Name
Extended Settings>Spectrum Sweeper>
FM unmute delay
PSREdit Name
- Weather/Advanced Configuration>Sweeper/Search
Options>
Unmute Delay (FM Mode)
SpclStalk(Sweep)Lmt
The maximum number of Special Stalker/Sweeper lockouts per range before skipping that range.
Default Value 5
(lockouts).
Values:
Enter
1-20
(lockouts).
Menu Help Text:
Special Stalker/Sweeper lockout count before skip
Win500 Name
Extended Settings>Spectrum Sweeper>
'Special' lockout limit
PSREdit Name
- Weather/Advanced Configuration>Sweeper/Search
Options>
Max Lockouts Per Range in SPCL
Zeromatic Settings
Zeromatc Cal
Customize the zeromatic tune threshold values for 5kHz ranges and non-5kHz ranges (entrance low value and high value, exit low value
and high value). See also [
].
Default Values:
Suggested Values:
]
Menu Help Text:
Zeromatic tune thresholds
5kHz In Lo-
252
5kHz In Hi-
552
5kHz Out Lo-
210
5kHz Out Hi-
594
In Lo-
210
In Hi-
594
Out Lo-
174
Out Hi-
633
5kHz In Lo-
170
5kHz In Hi-
480
5kHz Out Lo-
150
5kHz Out Hi-
530
In Lo-
170
In Hi-
480
Out Lo-
150
Out Hi-
530
Values:1-1023
Win500 Name
- Extended Settings>
Zeromatic Thresholds
PSREdit Name
- Weather/Advanced Configuration>
ZeroMatic Settings
ZM Delay
Zeromatic check delay.
Default Value 5
(5 ms).
Values:
Enter
0-1000
(0 - 1000 ms).
Actually only able to enter values up to
100
]
Menu Help Text:
Zeromatic check delay
Win500 Name
- Extended Settings>
ZM Check delay
PSREdit Name
- Weather/Advanced Configuration>ZeroMatic Setting>
Check Delay
Weather Settings
WX Check Int
Interval of time to check for a weather alarm signal on a channel while scanning (WX Priority). See also
.
Default Value 60
(6 seconds).
Values:
Enter
5-250
(
.
5 - 25 seconds).
Menu Help Text:
Weather 1050 chk interval in SCAN and MAN modes
Win500 Name
- Weather Settings>Weather Priority Settings>
Check interval
PSREdit Name
- Weather/Advanced Configuration>Timer Settings>
1050 Hz Tone Detect Threshold
WX 1050Hz Th
Length of time to wait on the weather frequency to check for the alarm signal.
Default Value 20
(200 ms).
Values:
Enter
7-250
(70 - 2500 ms).
Menu Help Text:
Weather 1050Hz qualify time
Win500 Name
- Weather Settings>Weather Priority Settings>
1050Hz qualifier
PSREdit Name
- Weather/Advanced Configuration>Timer Settings>
Timeout
WX Alrm Time
Length of time to wait before unmuting the weather frequency after an alarm.
Default Value 0
(0 seconds).
Values:
Enter
0-600
(0 - 600 seconds).
Menu Help Text:
WX SAME alert time to unmute 0=unmute @1050
Win500 Name
- Weather Settings>Weather Priority Settings>
Alarm timeout
PSREdit Name
- Weather/Advanced Configuration>Timer Settings>
Alarm Settings: Length
WX Lstn Time
Length of time to listen to the weather frequency after an alarm unmuted the radio.
Default Value 90
(90 seconds).
Values:
Enter
30-999
(30 - 999 seconds).
Menu Help Text:
WX Listen Time Auto-remute time after unmute
Win500 Name
- Weather Settings>Weather Priority Settings>
Listen time
PSREdit Name
- Weather/Advanced Configuration>Timer Settings>
Listen
Misc Settings
FlexStep
When set to '
On
' allows you to enter a frequency down to any 1250 Hz (1.25 kHz - .00125) step (except in the civil air band 108-136 where the
step size is fixed at 8.333 kHz), otherwise the scanner will use the
Default Value Off
.
Values:
◄
or
►
to
Off/On
.
Menu Help Text:
On= Allow any 1250Hz freq Off=Enforce fixed steps
Win500 Name
- Extended Settings>
Enable FlexStep
PSREdit Name
- General Configuration>Other Options>
Enable FlexStep
ADC Cal
Allows you to customize the information shown in the display while in 'Tune' mode. See also
Analyzing Trunking Systems
.
Default Value Off
.
Values:
◄
or
►
to
OFF
.
Menu Help Text:
Show various data within Tune Mode on LCD line 3
Win500 Name
- Extended Settings>
PSREdit Name