Press
▼
or
▲
to scroll to the trunked system and press
FUNC
then
L/OUT
to toggle temporary lockout or
L/OUT
to toggle permanently lockout for the
system.
Unlocking Objects
See also
Find by L/O Status
.
To Unlock a Conventional, Talkgroup, or Search Object:
(to unlock search frequencies
within
search objects see
Unlocking Search Frequencies
).
In Manual or Program Mode, press
◄
or
►
to select the Scan List where the object is located.
Press
▼
or
▲
to locate the object in the list.
To unlock a temporary lockout press the
L/OUT
button.
The flashing lowercase '
l
' in the display turns solid to show the object is unlocked.
To unlock a permanent lockout press
FUNC
then the
L/OUT
button.
The uppercase '
L
' in the display changes to the lowercase '
l
' to show the object is
unlocked.
To Unlock a Trunked System:
Press
PGM
then
F2
(
EDIT
). Press
►
until
TSYS
is over
F3
then press
F3
(
TSYS
).
Press
▼
or
▲
to scroll to the trunked system and press
FUNC
then
L/OUT
to toggle temporary lockout or
L/OUT
to toggle permanently lockout for the
system.
Priority Scanning
To Turn Priority Scanning On
press
FUNC
then
PRI
while scanning. All objects with their priority mode set to '
On
' are given equal priority status. No
object has higher priority over any another.
Conventional
Priority Scanning
will give priority to conventional objects that have their
. The scanner will sample the
conventional objects for activity periodically while scanning and monitoring other objects. This sampling will cause a brief muting of received audio when it
occurs while another object is active. The more conventional objects that are set for priority, the longer this audio muting will be, since it takes a certain
amount of time to sample each priority conventional object for activity. It will not check for conventional objects when scanning search or Stalker/Sweeper
objects.
Talk Group
Priority Scanning
will give priority to IDs that have their
priority on are checked for activity before any
other IDs and during the delay time after non-priority ID calls
. On some trunked systems (e.g. Mot 3600 if the system is programmed for it, and LTR
for some talkgroups), it will look at low-speed data on the voice frequency checking for any priority Talk Group information.
It will not check for IDs when receiving any other talkgroup.
It will not check for IDs when scanning conventional, search, or Stalker/Sweeper objects.
Priority does work for Radio IDs associated with 'Private' IDs.
Priority does
not
work for Radio IDs associated with 'Group' IDs, the scanner will only check the 'Group' IDs.
See also these Priority settings in the GLOB Menu:
The
Priority Channels
setting sets the number of
conventional
priority channels to check during priority scan (
default
=
0
).
The
Pri Interval
sets how often the scanner checks the priority channels (
default
2 secs
).
setting when set to '
On
', (default 'Off') will not wait for verification of correct CTCSS, DCS, or NAC when returning to an active
conventional channel after priority sampling.
The
TGRP Pri Int
setting will interrupt trunked activity to check for conventional priority channels when set to (default) '
On
'.
Weather
Priority Scanning
will give priority to a weather channel that has its priority mode set to '
On
'. Weather Priority mode samples the specified
weather frequency periodically while scanning to see if the 'All Hazards 1050 Hz Warning Alert Tone' (WAT) is present. If the WAT is present, the scanner
will sound an alarm and tune to the specified weather frequency to monitor the nature of the alert.
The
WX Check Int
setting (in the '
Expert Settings
' menu) allows you to set the interval of time to check for a weather alarm signal on a channel while
scanning.
Using the Attenuator
The attenuator reduces the amount of signal at the receiver input (20 dB) and may help reduce interference from strong nearby transmitters. There are
two attenuation modes, Normal and Global. Normal attenuation uses the attenuation settings for each object or search. Global attenuation forces
attenuation for all objects, on or off
To Attenuate a Conventional Object
press
ATT
anytime a conventional object is in the display.
To Attenuate a Trunking System
press
ATT
anytime a talkgroup object is in the display.
To Attenuate a Search Object or Dedicated Search
press
ATT
during the search.
To Turn Global Attenuation Mode Off
press
FUNC
then
ATT
(no
G
in the display).
To Turn Global Attenuation Mode On
press
FUNC
then
ATT
(
G
in the display).
To Turn Global Attenuation On
press
ATT
(
GA
in the display).
To Turn Global Attenuation Off
press
ATT
(
G
in the display).
Using the Favorites List and Skywarn List
The Favorites List and Skywarn List are 2 list that can be scanned independently from the regular 20 lists. They scan the objects in their list only and no
other lists. The Skywarn list is really just another Favorites list. The Favorites List is scan list #21 and the Skywarn List #22 when selecting lists in the
menus. Objects in the Skywarn and Favorites lists can also be assigned to one or more of the other 20 lists.
The Favorites List is an easy way to scan one or just a few objects at a time without reprogramming anything as it is easy to add objects or clear the list.
To Add an object to the Favorites List
press
FUNC
then
FAV
when the object is in the display. Or, when programming an object, select '
21
' in the '
Scan
Lists:
' option of the menu or '
Yes
' in the '
FAV:
' option of the menus.
To Scan the Favorites List
press
FAV
. Press
SCAN
to exit.
To Clear the Favorites List
press
PGM
then
GLOB
, scroll down to '
Clear FAV
' and press
SEL/ENT
. At '
Really remove all objects from FAV scan list?
',
press
F1
(
YES
).
The Skywarn list is meant to be a more permanent list. Although the manual states "Instant access to frequencies used by storm spotter networks", you
still have to program the frequencies yourself.
To Add an object to the Skywarn List
when programming an object, select '
22
' in the '
Scan Lists:
' option of the menu or '
Yes
' in the '
SkyWarn
:' option
of the object menu.
To Scan the Skywarn List
press
FUNC
then
WX
. Press
SCAN
to exit.