11
Problem solving
The ScanDust 6000 dust extractor is designed and manufactured for severe environments and tasks, but the
user should note that the machine components must be protected from knocks and blows. Filter, seals,
attachments, and connections are carefully adapted and selected with regard to the operator’s work
environment. Therefore, the machine must be treated with care if it is to work correctly for many years.
Problem
Cause
Procedure
Motor does not start
No power
Connect the machine
Switch defective
Change
Motor stops immediately
Wrong fuse
Connect the right fuse
after starting
Motor runs, but there is
Hose not connected
Connect the hose
no suction
Hose blocked
Clean the hose
No plastic bag
Fit plastic bag
Motor runs but suction Damage to the hose
Change hose
is poor
Filter blocked
Change filter
Top cover loose
Adjust
Dirt in the flap
Clean the flap.
Use protective equipment
Sealing defective
Change current seal
Dust blows from motor
Filter defective or loose
Adjust or change
Abnormal noise
Order service
KEEP THESE INSTRUCTIONS!