RTC
®
5 PC Interface Board
Rev. 1.9 e
10 Commands And Functions
552
innovators for industry
Ctrl Command upload_transform
Function
transfers from the RTC
®
5 board to the PC all correction and transformation settings
currently assigned to the scan system.
Call
UploadErrorCode = upload_transform( HeadNo, Ptr )
Parameters
HeadNo
Number of the scan head connector whose settings should be queried, as an
unsigned 32-bit value; allowed values:
= 1:
primary scan head connector
= 2:
secondary scan head connector (activation required)
Ptr
Pointer (in C and C
++
data type ULONG_PTR, i.e. an unsigned 32-bit or 64-bit
value) to the PC’s area of memory that should receive the queried settings
Result
error code as an unsigned 32-bit value:
Bit #0
=1:
X gain (gain of automatic self-calibration for galvanometer 2) = 0
Bit #1
=1:
Y gain (gain of automatic self-calibration for galvanometer 1) = 0
Bit #2
=1:
The total matrix of the defined coordinate transformation is noninvertable
Bit #3
=1:
No correction table assigned
Bit #4
=1:
The ABC values (Z axis) are noninvertable
Bit #5
=1:
Error querying correction table
Bit #6
=1:
Parameter error: invalid
HeadNo
or
Ptr
= 0
Bit #7
=1:
BUSY error, board was BUSY or INTERNAL-BUSY (
return code
RTC5_BUSY
).
Bits #8..#31
reserved
Comments
• The queried and transferred data can be used for backward transforming actual posi-
tion values via
or
(also see
• For storage of each queried data set, the application must provide (at an address spec-
ified by
Ptr
) an area of PC main memory equal to 528520 bytes.
• In case of error (except for bit#6 = 1), an error indication will be stored at
Ptr
to indi-
cate that the data are erroneous. The commands
will
recognize this error information and will ensure that the backward transformation is
not executed (
then generates a corresponding error code,
generates a
return code of
RTC5_PARAM_ERROR
).
:
RTC5_BUSY
) if the addressed
board’s BUSY status is currently set (list is being processed or has been halted via
) or the board’s INTERNAL-BUSY status is currently set. In contrast, the
command is executed when a list has been paused via
PAUSED status set).
• During execution of the command, external list starts will be suppressed.
RTC
®
4
RTC
®
5 new command
Version info
Available beginning with version DLL 516, OUT 515, RBF 512
References
,