10 Commands And Functions
529
innovators for industry
Version info
• Available beginning with version DLL 515, OUT 514, RBF 512
• Updated with version DLL 518, OUT 517, RBF 515: enhanced master/slave synchroniza-
tion (see
); we recommend only using the updated version of the command.
• Updated with version DLL 523, OUT 524: also triggers matching of short-command
counts when necessary (see
).
References
Normal
List Command
time_fix
Function
stores the current time and date of the RTC
®
clock/calender in a buffer for use with
Call
time_fix()
Comments
• The command
time_fix
is synonymous with
FirstDay
= 0 and
Offset
= 0 (see comments there).
RTC
®
4
RTC
®
5 unchanged
(the command was previously only available for the RTC
®
SCAN
alone Board, i.e. the
standalone version of the RTC
®
4 board)
Version info
Last change with version OUT 517
References
Normal
List Command
time_fix_f
Function
stores the current time and date of the RTC
®
clock/calender in a buffer for use with
Call
time_fix_f( FirstDay )
Parameter
FirstDay
Comments
• The command
time_fix_f
with
Offset
= 0 (see
comments there).
RTC
®
4
RTC
®
5 new command
Version info
Last change with version OUT 517
References
Ctrl Command sync_slaves