RTC
®
5 PC Interface Board
Rev. 1.9 e
10 Commands And Functions
423
innovators for industry
Normal
List Command
set_ext_start_delay_list
Function
same as
(see above), but a list command
Call
set_ext_start_delay_list( Delay, EncoderNo )
Parameters
Delay
See
.
EncoderNo
See
.
Comments
• If
EncoderNo
> 1, then
set_ext_start_delay_list
(
return code
RTC5_PARAM_ERROR
).
RTC
®
4
RTC
®
5 See
References
Ctrl Command set_firstpulse_killer
Function
defines the length of the FirstPulseKiller signal for a YAG laser
Call
set_firstpulse_killer( Length )
Parameter
Length
length of the FirstPulseKiller signal as an unsigned 32-bit value.
1 bit equals 1/64
µ
s.
Allowed range: [0 … +(2
26
–
1)]
Comments
• Values over (2
26
–
1) will be clipped.
• The time base for the FirstPulseKiller signal is always 64 MHz (i.e. 1 bit equals 1/64
µ
s).
• The signal level is defined via
• For YAG mode 2, the Q-Switch delay will also be correspondingly altered (see
• In CO
2
mode, the command
has no effect.
• The laser control mode has to be set via the command
chapter 7.4 "Laser Control", page 128
for details.
• To set the Q-Switch pulse length and period, use the commands
,
.
RTC
®
4
RTC
®
5 essentially identical functionality (except for the extended range of values), however:
Length
must be specified in units of 1/64
µ
s with the RTC
®
5; in RTC
®
4 compatibility mode
it must be specified in units of 1/8
µ
s (as with the RTC
®
4). In RTC
®
4 compatibility mode,
the RTC
®
5 multiplies the specified value for
Length
by 8 (the permissible range of values is
correspondingly reduced).
References
Undelayed
Short
List Command
set_firstpulse_killer_list
Function
same as
(see above), but a list command
Call
set_firstpulse_killer_list( Length )
Parameter
Length
length of the FirstPulseKiller signal as an unsigned 32-bit value.
1 bit equals 1/64
µ
s.
Allowed range: [0 … +(2
26
–
1)]
RTC
®
4
RTC
®