RTC
®
4 PC Interface Board
Rev. 1.3 e
10 Commands And Functions
78
innovators for industry
0528
H
Flags B15 ... B0 [0 ... 65535]: Current operational state
Bit #15 (MSB)
= 1:
Galvanometer scanner’s output stage is on
Bit #14
= 1:
Galvo heater’s output stage is on
Bit #13
= 1:
Internal voltages normal
Bit #12
= 1:
Position error within normal range
Bit #11
= 1:
Galvo and servo board temperature within normal range
Bit #10
= 1:
Booting process completed
Bit #9
= 0:
A critical error occured. The system was switched into a
permanent error state.
Bit #8
= 0:
The external power supply voltages have – at least temporarily –
dropped below the allowed value
Bit #7
= 0:
The temperature in the intelli
SCAN
®
excceds the maximum
allowed value. The system was switched into a temporary error
state.
Bit #6
= 1:
The AD converter was successfully initialized
Bit #5
= 0:
The galvanometer scanner has reached a critical edge position
Bit #4
= 1:
All control parameters valid
Bits #1-3
Reserved
Bit #0
= 0:
The control is activated, as soon as all necessary flags are set
0529
H
Flags B31 ... B16 [0 ... 65535]: Current operational state
Bit #31(MSB)
= 1:
AGC voltage (PD supply voltage) o.k.
Bit #30
= 1:
Analog section voltage (9 V) o.k.
Bit #29
= 1:
AD converter supply voltage (5 V) o.k.
Bit #28
= 1:
DSP IO voltage (3.3 V) o.k.
Bit #27
= 1:
DSP core supply voltage (1.8 V) o.k.
Bit #26
= 1:
Servo board operation temperature reached
Bit #25
= 1:
Galvanometer scanner operation temperature reached
Bits #16-24
Reserved
052A
H
Stop Event Code [0 ... 65535]
= 0001
H
:
The galvanometer scanner has reached a critical edge position
= 0002
H
:
AD converter error
= 0003
H
:
The temperature in the intelli
SCAN
®
has excceded the maximum
allowed value
= 0004
H
:
External power supply voltages have dropped below the allowed value
= 0005
H
:
Flags are not valid
= 0006
H
- 000C
H
:
Reserved
= 000D
H
:
Watchdog 10
µ
s time out (loop time exceeded)
= 000E
H
:
Position Acknowledge time out (set position not reached for long time)
= 000F
H
:
Reserved
052B
H
Flags B15 ... B0 on stop [0 ... 65535]: Operational state at the moment of
the most recently occured operation interruption (see
code 0528
H
)
052C
H
Flags B31 ... B16 on stop [0 ... 65535]: Operational state at the moment of
the most recently occured operation interruption (see
code 0529
H
)
052F
H
Running time (seconds) / s [0 ... 59]
0530
H
Running time (minutes) / min [0 ... 59]
0531
H
Running time (hours) / h [0 ... 23]
0532
H
Running time (days) / d [0 ... 65535]
Ctrl Command control_command