Air cleaner
Reading the vacuum indicator
If the indicator's red plunger is fully visible, re-
new the air cleaner filter element following the
instructions.
Renewing the filter element
Note:
Renew the filter element earlier than the inspec-
tion interval if the indicator shows red.
There is always a risk that the filter element will
be damaged when it is cleaned.
The filter element must not be cleaned in water
or be blown clean with compressed air.
WARNING!
Never start the engine without the air filter as this
could cause injury and severe engine damage.
1.
Remove the cover from the air cleaner.
2.
Renew the filter element.
3.
Carry out a check by inserting an inspection
lamp into the element and checking from the
outside that there are no holes or cracks in the
filter paper.
4.
Assemble the air cleaner.
5.
Reset the vacuum indicator by pressing the
button.
326 671
A
B
336 100
A Vacuum gauge