Cave 40/100/100S
Cave 40
Exterior dimensions
w595 x h845-895mm x d546mm/
581mm with handle
(carcass height 700 mm)
Capacity
Ca 40 bottles
Defrosting
Automatic
Weight
43 kg
Energy consumption
0,353 kWh
Thermostat setting
8-15 °C
Ambient temperature
10-27 °C
Insulation
Polyurethane foam, CFC-free
Compressor
Danfoss
Cooling agent
R134A
Volt/Hz
220-240V AC 50Hz
Cable connection length 2,6 m
Door hanging
Right
Cave 100
Exterior dimensions
w595 x h1730 x d650mm/
687 with handle
Capacity
Ca 100 bottles
Defrosting
Automatic
Weight
83 kg
Energy consumption
0,76 kWh
Thermostat setting
8-15 °C
Ambient temperature
10-27 °C
Insulation
Polyurethane foam, CFC-free
Compressor
Danfoss
Cooling agent
R134A
Volt/Hz
220-240V AC 50Hz
Cable connection length 2,4 m
Door hanging
Right
Cave 100 S
Exterior dimensions
w595 x h1730 x d650mm/
672 with handle
Capacity
Ca 100 bottles
Defrosting
Automatic
Weight
85 kg
Energy consumption
0,76 kWh
Thermostat setting
8-15 °C
Ambient temperature
10-27 °C
Insulation
Polyurethane foam, CFC-free
Compressor
Danfoss
Cooling agent
R134A
Volt/Hz
220-240V AC 50Hz
Cable connection length 2,4 m
Door hanging
Right
Integration
Cave 40
When integrated into a fitted kitchen, air intake is ensured by using the grille supplied fitted into
the plinth under the cabinet. The grille area is 126 cm
2
. If you wish to use a different grille to that
supplied with the cabinet, ensure it has at least the same size. Exhaust air passes through the
grille mounted on the top of the cabinet, and which must not be covered.
NOTE: Failure to ensure sufficient air circulation is not good for the cabinet and reduces its
service life.
Cabinet width is 595 mm, and it requires a space of 600 mm wide to provide a gap of 5 mm either
side, to prevent restricting door opening and closing.
Cabinet height can be adjusted by the adjustable legs, to ensure the top of the cabinet is flush with
the underside of the worktop. NB: ensure the cabinet is level.
When the cabinet has been correctly positioned, check that the electric cable does not pass any
sharp edges and is not jammed under the cabinet. Leave the plug underneath the cabinet and do
not insert it in the mains socket until you have completed the installation.
Cut an opening for the air intake grille in the plinth (225mm x 94mm). Fit the grille into the opening.
(see figure 1 on next page)
4
Содержание Norcool Cave 100
Страница 1: ...Cave 100 100S Cave 40 Norsk Svensk Suomi English ...
Страница 4: ...Cave 40 100 100S Mål og tekniske spesifikasjoner 3 ...
Страница 13: ...3 Mått och tekniska specifikationer ...
Страница 20: ...Cave 40 100 100S Mitat ja tekniset tiedot 3 ...
Страница 27: ...Dimensions and technical specification 3 ...
Страница 34: ...Trehylle Wooden shelf 1115990790 6 ...
Страница 35: ......