- Ergo Line & Banquet Line Active Cooling
Unpacking
Do not scratch the boxes when unpacking
Recycling of Packaging Materials
First Cleaning
Commissioning
ScanBox packaging materials can be returned to the recycling station
The boxes are cleaned by ScanBox personnel before they were transported, but you should always
clean the boxes one more time before using them
ScanBox products meet relevant electrical specifications Before using the boxes for the first time,
please follow below instructions:
• Make sure that the mains voltage is in accordance with the box’s specification
• The wall socket must be easily accessible making sure the box can be disconnected by hand with-
out pulling the cord
• Boxes with compressor cooling should not be transported while lying down If the box has been
laying down during transport, allow it to stand up for at least two hours before switching it on This
to ensure the compressor oil flows back into place
Daily Use
Declaration of Conformity with CE
The box should be connected to a grounded 220-240V single phase wall socket for 90-120 minutes
before using the box If the box is equipped with compressor cooling, 40-60 minutes is enough to cool
the box to the desired level The box comes with a spiral cable to be plugged into a wall socket at the
appropriate height The spiral cable is located on the back of the box
After loading the food into the box, connect the box to a wall socket for another 10-15 minutes for best
results This allows the temperature to be restored after the frequent door openings during loading
• The purpose of a box with active cooling is to hold and transport cold food, not to cool down food
Boxes with compressor cooling meet climate class 4 This means that the boxes can keep an inside tem-
perature of 3-8°C in an ambient environment with a temperature of 30°C and a humidity of 55% RH
Boxes with peltier cooling meet climate class 0 This means that the boxes can keep an inside tempera-
ture of 3-8°C in an ambient environment with a temperature of 20°C and a humidity of 50% RH
This product meets the safety requirements of the Machinery Directive 2006/42/EC In addition, the
product complies with the EMC Directive 2014/30/EU and the 2011/65/EU Directive on the Use of
Certain Hazardous Substances in Electrical and Electronic Equipment (”RoHS2”) Furthermore, the
manufacturer fulfills the requirements of Regulation 1907/2006/EC on the Registration, Evaluation,
Authorization and Restriction of Chemical Substances (”REACH”)
For the latest updates regarding “EU Declaration of Conformity”, visit
wwwscanboxse/en/support