DSA 1 free standing
DSA 1 built-in
Warranty conditions
All SCAN wood-burning stoves and inserts are made of
first-class material and are subject to a strict quality control
before they leave the factory. However, if an error should
occur, we back all SCAN wood-burning stoves and inserts
with an extensive, five-year limited warranty.
See also the
General Instructions for Installation
delive-
red with your insert for more details.
Distance to flammable materials (mm)
Production number
Write the production number of your
insert here so that you have it at hand
in case you need to contact us.
SCAN DSA 1
706 / 662
808
874
729
Min. distance to the ceiling: 250 mm
1825
1555
Data for calculation of the chimney (DIN 18891)
*) The data are based on the German test
results according to DIN 18891 with a Ø 180
flue outlet.
Stove
model
SCAN
Connecting
adaptor
mm
1
Density of
flue gas
flow
g/s
2
Flue gas
tempera-
ture
oC
3
Minimum
draft
Pa
4
Density of
flue gas
flow
g/s
5
Flue gas
temperature
oC
6
Minimum
draft
Pa
7
0.8
Minimum
draft
Pa
DSA 1
200 *)
-
-
-
14
220
15
11
With closed doors
With open doors
Columns 2 and 5 show the flue gas temperature in the connecting adaptor
Columns 3 and 6 show the lowest/minimum draft in Pa by rated value
Columns 7 shows the lowest/minimum draft in Pa by 0.8 x rated value
200
1200
1200
460
460
Floor
plate
Floor
plate
Radiation area
Radiation area
300
300
500
300
300
500
*) 1640
*) Height to the beginning of the flue pipe (top outlet)
Technical info
Emission (% CO at 13% O2):
0.11%
Efficiency:
74%
Rated output:
10 kW
Chimney temperature:
220 oC
Flue outlet flow:
14 g/sec
Recommended low pressure in conn. piece: 15 Pa
Recommended fuel:
Wood
Amount of fuel and consumption:
3,22 kg/h
Min./max. (information from the factory): 8-11 kW
Weight, built in:
225 kg
Weight, freestanding:
226 kg
Connection piece, int. diameter:
200 mm
Connection piece, ext. diameter:
204 mm