background image

You have chosen a product from one of Europe's leading manufacturers of wood-burning stoves. We are convinced that 
your stove will be to your full satisfaction and give you many hours of pleasure if you follow the advice and instructions of 
this manual.

Please read this manual as well as the General Instructions for Installation before beginning the installation.

Congratulations on your new SCAN stove! 

Ceramic smoke deflectors

Ashtray.

 When you open the door, you have access to 

the ashtray, which is placed below the combustion cham-
ber. 

Attention! Be careful when you empty ashes from the 

stove. There may be embers left for up to 24 hours after 
the stove was last used.

2  

Handle for shaking grate.

 The stove is equipped with a 

shaking grate. When you activate the grate handle, the 
ashes from the combustion chamber are emptied into the 
ashtray.

Regulation for primary air.

 Pull out the handle in order 

to open. The primary air is used when lighting and 
refuelling the stove. It should always be closed during 
continuous firing.   

 

 

 

Air for lighting of the stove. 

Tilt down and pull out the 

handle for extra air when lighting the stove and when 
refuelling. 

It should always be closed during conti-

nuous firing.

 

Clean combustion

The SCAN Andersen 10 uses the "CB technique" 
(Clean-Burn) to ensure an optimally clean combu-
stion. The extra combustion air is preheated and led 
into the combustion chamber close to the ceramic 
smoke deflector. 

Ceramic smoke deflectors

 

Lift up the lower ceramic smoke deflector, pull out the 
pins in the lateral combustion chamber plates and 
remove the deflector. The upper deflector is removed 
in the same way.

SCAN Andersen 10

1

3

2

3a

3a

The shaking grate and primary air should always be clo-
sed during continuous firing.