background image

1.

2.

3.

4.

5.

30

Continuous firing

It is important to reach as high a temperature as possible in the 
combustion chamber. This makes the most efficient use of the wood 
stove and fuel, and ensures a clean burning process. At the same 
time, this avoids soot build-up on the combustion chamber walls and 
glass. While the stove is lit, you should not see any smoke, but just air 
movement that indicates the burning process. 
After completing the lighting phase, you should have a good layer of 
embers in the wood stove; you can then start stoking up the stove. 
Lay 1-3 pieces of wood, of about max 1,7 kg weight with max 10 cm 
diameter and a length of about 25 cm onto the fire.
Note! The wood must catch fire quickly; this is why we recommend 
setting the primary airflow to full power. Running the stove at too 
low a temperature and with too little primary air can lead to defla-
gration of the gases, and thus cause damage to the stove.
When stoking up with wood, always open the glass door carefully to 
avoid smoke escaping. Never stoke up with wood while the fire is still 
burning nicely.

Environmentally-Friendly Heating

Avoid restricting your wood-burning stove to an extent where no 
flames are visible during the degasifying period, as this leads to 
particularly inefficient heating. The gases released by the wood 
do not burn due to the low temperature in the combustion cham-
ber. Part of the gas condenses in the wood-burning stove and flue 
system as soot, and this could lead to your chimney catching fire. 
The smoke that exits the chimney is bad for the environment and 
has an unpleasant smell.

Lighting

We recommend the use of fire starters, or similar products, which are 
available from your Scan dealer. Using fire starters helps to light the 
wood quicker, and keeps the burning process clean.
Never use liquid lighting fuels!

"Top down" lighting

Important! Always use a top-down lighting. The stove is constructed 
for this in order to give the best exploitation."Top down" lighting is 
a more environmentally friendly way of lighting the fire and helps to 
keep the glass area as clean as possible.

2 pieces of wood approx. 20-25 cm long with a weight of approx. 
0.5–0.6 kg per piece (image 1)

The wood must not cover the bottom entirely and must never be 
placed higher than the Clean-Burn rail at the rear of the stove.

1 pieces of wood approx. 0.3–0.4 kg (image 2) 8-12 thin sticks of about 

20 cm with a total weight of approx. 0,5 kg (image 3-5).3 fire starters.

Place logs, sticks and fire starters in the combustion chamber as 
shown on images

 1-5. 

Set the primary and secondary air controls to maximum in the 
lighting phase. If the fire is too strong, you may throttle down the 
primary air damper (at the left).

I N S T R U C T I O N S   F O R   H E AT I N G

Содержание 66 series

Страница 1: ...our new Scan wood burning stove You have purchased a product by one of Europe s leading manufacturer s of wood burning stoves and we are sure that you will have years of pleasure with your purchase To...

Страница 2: ...wn with insulated ue pipe Distance to ammable materials shown with un insulated ue pipe Distance to rewall Height adjustment of stove Load bearing foundation Floor plate Existing chimney and pre fabri...

Страница 3: ...bliged to have the installation inspected and approved by a local chimney sweep prior to commissioning To ensure best possible functionality and safety for your installation we advise you to call a pr...

Страница 4: ...get the best use of the stove by using a top down lighting see page 28 Technical data and dimensions Materials Steel plate cast iron galvani sed sheet vermicolite Surface treatment Senotherm Max wood...

Страница 5: ...t 171 366 483 51 185 Centre rear outlet Height to the beginning of the connecting piece at top outlet Fresh air intake at the back of the stove Centre of fresh air intake bottom Connecting piece top o...

Страница 6: ...2 366 483 Front 6 Centre rear outlet Height to the beginning of the connecting piece at top outlet Fresh air intake at the back of the stove Centre of fresh air intake bottom Connecting piece top outl...

Страница 7: ...366 481 532 Front Dimension sketch Scan 66 4 Plinth TEC H N ICAL DATA Centre rear outlet Height to the beginning of the connecting piece at top outlet Fresh air intake at the back of the stove Centre...

Страница 8: ...8 943 630 337 313 301 171 166 881 796 430 1037 428 168 5 Dimension sketch Scan 66 5 S Curve TEC H N ICAL DATA...

Страница 9: ...mittent EUR Norway Classification Intermittent Klasse 2 Certificate Standard EN 13240 ELAB 2081 NS Approved by Teknologisk Institut Teknologisk Institut Dust at 13 O2 27 mg Nm Flue gas temperature 302...

Страница 10: ...tral product or sent for recycling POLYSTYRENE TOP Send for recycling or waste disposal FOAM Send for recycling or waste disposal PLASTIC BAGS Send for recycling or waste disposal STRETCH FILM PLASTIC...

Страница 11: ...at output 5 kW Efficiency 78 Scan A S DK 5492 Vissenbjerg Minimum distance to combustible materials Side 300 mm Front 850 mm CO emission at 13 O2 Follow assembly and instructions manual Use only recom...

Страница 12: ...portant that it is level Mount bushing screw and nut Dismount the rear plate by removing the four screws Place the rear plate on an even surface Remove the slits use a drilling machine and nippers Mou...

Страница 13: ...ting in between Screw the rails and the bottom plate together in the sides Tighten the four bottom screws Tighten up all screws Mount the bottom plate on the existing four screws Let the rails glide d...

Страница 14: ...DK 5492 Vissenbjerg Minimum distance to combustible materials Side 300 mm Front 850 mm CO emission at 13 O2 Follow assembly and instructions manual Use only recommended fuels Montage und Bedienungsanl...

Страница 15: ...division plate External combustion air from the rear Mount the delivered cover plate then the pedestal The cover plate from the rear is not to be reused Fasten the screws External combustion air from...

Страница 16: ...16 Scan 66 4 ASSEMB LY Prepared for external air at the bottom Cut out the hole with a pair of cutting nippers Fasten the four screws after mounting the base...

Страница 17: ...left of the stove Fasten the screws lightly so that it is possible to lift the stove with base up Make sure that the S base is horizontal if necessary use a spirit level Adjust the stove on the base a...

Страница 18: ...ASSEMB LY 1 Scan 66 stove body 6 Skamol plates 2 pins for baffle plates 1 connecting piece for external combustion air 1 log guard made of glass Opening of the door Push the handle backwards in order...

Страница 19: ...ind the grate Rear plate mounted Fit the left side plate in at the top Slide the plate in place Left side plate mounted Mount the right side plate in the same way as the left plate Right side plate mo...

Страница 20: ...e taken into use Push the plate a bit backwards so that it rests on the rail in the back Lower baffle Let the plate rest on the rail with the air slots Push the plate backwards in order to mount the p...

Страница 21: ...recommend a distance of 50 mm in order to facilitate the cleaning of the stove the ue pipe and the chimney and to prevent possible damages to the wall Distance to furniture 850 mm You should however...

Страница 22: ...with insulated flue pipe The distances presuppose the use of an insulated flue pipe all the way to the stove Parallel rear wall installation Parallel rear wall installation 45 Corner installation 45...

Страница 23: ...200 50 750 500 750 50 50 50 750 750 23 The indicated distances are valid for insulated as well as un insulated smoke pipes Flammable material Firewall ASSEMB LY Distance to firewall...

Страница 24: ...le floor you must comply with the national and local regulations on the size of any non flam mable foundation required to cover the floor around the stove Your local Scan dealer can advise you on regu...

Страница 25: ...wood burning stove As a general rule the length of the chimney should not be less than 4 metres measured from the top of the stove Specific weather or installation conditions might require a differen...

Страница 26: ...26 Click 1 3 2 4 ASSEMB LY Top outlet Rear outlet...

Страница 27: ...losed combustion system for the wood burning stove if you live in a newly built airtight home External combustion air is connected through a ventilation pipe via the wall or floor We recommend mountin...

Страница 28: ...t open Operation with the door open can cause excess smoke The appliance must not be operated with the appliance door left open except as directed in the instructions 1 Dampers left open Operation wit...

Страница 29: ...ndary airflow soot can build up on the glass pane The secondary airflow determines the heat output from your wood stove Settings for normal load 50 70 Baffle plates The baffle plates are located in th...

Страница 30: ...ient heating The gases released by the wood do not burn due to the low temperature in the combustion cham ber Part of the gas condenses in the wood burning stove and flue system as soot and this could...

Страница 31: ...imney fire keep the stove door the ash container and the valves on the stove closed In case of emergency call the fire ser vice It is recommended that you get a chimney sweep to check the chim ney bef...

Страница 32: ...Cleaning the glass Our wood burning stoves are designed to prevent serious soot build up on the glass The best way to achieve this is to make sure you have a sufficient combustion air supply It is als...

Страница 33: ...33 Pull out the ash drawer and empty it The glass log guard is easy to remove and can be clea ned with glass cleaner MAI NTENANC E Log guard Ash drawer...

Страница 34: ...o that it is freed from the fittings at the rear of the combustion chamber Then take out the plate We refer to page 13 for a detailed description of the mounting dis mounting of the burn chamber plate...

Страница 35: ...years on manufacturing errors or defects You must quote your stove s product registration number when you contact us or your authorised Scan dealer with a warranty claim The warranty covers all parts...

Страница 36: ...Scan A S DK 5492 Vissenbjerg 36 Version UK 90066500 06 03 2019...

Отзывы: