Installation
The house owner is responsible for ensuring that all necessary
national and local safety measures are observed during installation
and fitting and also responsible for observing the fitting and opera-
ting instructions detailed in this manual.
When you install any kind of fireplace or stove, you must inform the
local authorities. You are also responsible for calling in a chimney
sweep to inspect and authorize the installation.
To ensure best-possible functionality and safety for your installation,
we advise you to call a professional fitter. Our Scan Dealer will be
able to recommend a qualified fitter in your area.
Approval
If you intend to connect your stove to an existing chimney, it makes
sense to contact an authorised Scan dealer, or a local chimney
sweep for advice. These experts will also let you know if your flue
needs renovating.
On connecting to a multiple element chimney: follow the vendor‘s
instructions as applicable to the chimney type (e.g. Leca, Plewa,
Icopal, Isokern, Zanda etc.)
No matter whether an authorised Scan dealer installs your stove, or
you do the job yourself, remember that the chimney sweep has to
approve the installation before you start to use it.
Positioning the stove
The wood-burning stove must be set up so that the stove itself, the
flue pipe, and the chimney can all be cleaned.
Position in relation to non-flammable walls
When positioning near a non-flammable wall, keep a minimum
distance of 50mm between the rear of the product and the wall.
Technical data and dimensions
CO Emission at 13% O2: 0.12%
Efficiency: 73%
Rated heat load:
5 kW
Chimney temperature:
277 Cº
Flue outlet flow:
6.4 g/Sek.
Combustion air requirement:
19 Nm3/h
Recommended vacuum in flue colloar:
16 Pa
Recommended fuel:
Wood
Fuel capacity:
1.5 kg
Fuel consumption:
1.6 kg
Min./max. heating performance (vendor specification):
3-7 kW
Weight:
Scan Basic 4-2: 131 kg Scan Basic 4-2 K: 194 kg
Flue collar internal diameter:
135 mm
Flue collar external diameter:
148 mm
Approval type:
Intermittent fuelling
Intermittent fuelling means normal use of a woodstove. In other
words, you should let the fire die down until only the embers are left,
before refuelling.
The Scan Basic 4-2 & 4-2 K were build in compliance with the
homologised product type specified in the Assembly and Instruction
Manual provided with the product.
1
0
0
5
1
5
8
538
444
1
6
0
**
*
7
6
4
*
9
8
9
**
* Centre rear outlet
**
Height to beginning of
flue pipe at top outlet
*** Center of fresh air
intake
Distance to flammable walls
350
1
5
0
100
1
0
0
2
I N S TA L L AT I O N
9
8
9
**
1
0
0
5
7
6
4
*
1
6
0
**
*
1
6
0
532
446
* Centre rear outlet
**
Height to beginning of
flue pipe at top outlet
*** Center of fresh air
intake
Scan Basic 4-2
Scan Basic 4-2 K
Distance to furniture: 1000 mm.
You must also take into consideration whether the proximity to the
wood-burning stove will dry out your furniture and fittings.