background image

Programmable S81-HS system                                                 Installation and user manual 

 

 

Page 1  

of 3

 

 

 

S81-F7009-1

 

 

Description

 

  

Control card for addressable devices using XP95/Discovery Apollo protocol. This card can
control up to a maximum of 127 fire detection devices including :  smoke, heat, combined 
detectors, alarm buttons, control modules, visual and audible alarm devices.

 

 

Technical features

  

 

Redundancy:  

 

 

 

No 

 

Number of devices per loop 

 

 

127 

 

Loop maximum current 

 

 

400mA 

 

Supply voltage: 

 

 

 

22-29Vdc 

 

Quiescent current:  

 

 

 

90mA 

 

Operating temperature: 

 

 

-5 / +50 °C 

 

Storage temperature:   

 

 

-30 / +80 °C 

 

Maximum humidity: 

 

 

 

95% (RH) non condensing 

 

Hot swap capability:   

 

 

yes 

 

 
 
 
 
 
 
 
 
 

Status Indications  

The front panel includes 8 LEDs with the following functions: 
 

LED 

Indication 

Active 

Steady on if an input is under alarmed/activated condition 

 

Disabled 

Steady on if an input or an output is disabled

 

Fault 

Flashing in case of Fault condition

 

Loop Fault 

Flashing in case of loop short circuit or open loop

 

Log on Fault 

Flashing in case of difference between the detected devices and the programmed ones.

 

Service 

Flashing in case of in case of smoke detectors with dirty lenses

 

TX Pol. 

It lights up every time data are transmitted from the module to loop devices.

 

RX Pol. 

It lights up every time data from loop devices are received  

 
Configuration 

By using the configuration program ProS81, the following parameters can be set for each point of the single 
devices, according to the relevant type: 

 

Parameter 

Type 

Mode  

Operating mode  

Sensors 

Latching-NO, Latching-NC, Non-Latching-NO, Non-Latching-

NC 

Sensitivity 

Sensors 

5 sensitivity levels to be selected 

Type of indication  

Sensors 

Fire, Supervisory, Gas, Trouble, Hidden, Buzzer Only 

Automatic alarm reset 

Sensors 

Yes/No 

Operating mode 

Actuators 

Continuous-Normally Energised, Continuous-Normally De-

energised, Intermittent, Pulsing 

Timing 

Actuators 

1 to 15 seconds (only for pulsing and intermittent modes) 

Output type 

Actuators 

Normal / Sounder 

Sounder tone 

Actuators 

15 selectable tones 

Sounder volume 

Actuators 

7 selectable volume levels 

Polling LED 

Sensors/Actuators  Enable/Disable LED lighting up during polling 

Enable/Disable status export to 

Hosts 

Sensors/Actuators  No, TCP1, TCP2, RS232 

Enable/Disable commands 

from Hosts on the channel  

Sensors/Actuators  No, TCP1, TCP2, RS232 

 