AccuPro-5000
™
MEASUREMENT SYSTEM OPERATOR MANUAL
Issued by Department:
Engineering
Doc. Number:
5000-00-00-002
Revision:
02
Effective Date:
10/05/2021
File: 5000-00-00-002-r2_
AccuPro_5000_Operator_Manual
Copyright© 2021 Scaletron Industries, Ltd
All Rights Reserved
Page
8
of
63
2
System Specification Summary
System
Main Power
120/240 VAC +/- 10%, 50/60-Hz
Wattage: 74.7 W (maximum) @ 83% Efficiency
Fuse: 1.0A @ 120 VAC / 0.5A @ 240 VAC (5x20 mm, type slow-blow)
Connector: Sealed
DC Regulated
Power
Triple-Output: 5 VDC @ 4 A / +12 VDC @ 3 A / -12 VDC @ 0.5 A
Operational
Temperature
0
o
C to 60
o
C (32
o
F to 140
o
F)
Operational
Altitude
2000 meters (maximum)
Operational
Relative
Humidity
20% to 90% non-condensing
Enclosure
(Control-Panel)
Nominal Size: 8 x 8 x 4 Inches (LxWxD) with hinged cover
Weight: 6 lbs. (approx. maximum)
Material: Opaque Polycarbonate, UL Listed Type 4X NEMA
Location Recommendation: The Control-Panel should be operated in a
location that protects it from being soaked with liquids or exposed to
extreme weather conditions. If the system is to be located outdoors, you
must make sure not to exceed the operational temperature range. It is
further recommended that a covering be used to protect the indicator from
the elements. Locations inside buildings should be at a height that protects
it from chemical splashes and wash-down areas, but still allow for easy
operation of the Control-Panel.
Channels
Supports single or dual-channel configurations. Each channel is
independently controlled and operated.