When all external wire
connections are complete, close the panel’s door, secure
its latch, and re-install
the four screws (optional.)
4
System Hardware
The AccuPro-
5000™
hardware has been designed for modularity of function. This concept enables
each channel to be configured more efficiently through selection of optional circuit boards
–
all
interconnected via a common backplane. Upon power-up, the system scans the configuration of circuit
boards and presents a tailored suite of HMI control menus to the user.
System power is provided via a high-efficiency, triple-output, AC-to-DC supply that features short-
circuit protection.
4.1
Liquid Crystal Display (LCD) Board
With reference to Figure 1, the LCD Board manages the HMI controls and indicators. The on-board
AVR processor continuously scans the control panel for Keypad switch closures and/or Rotary Knob
rotation which the
software first debounces for mechanical noise. These “control events”
are buffered
before being communicated to the Main Processor Board via a polling algorithm. An LCD Module and
Status LED Array provide real-time, visual notification of system operation. Up to 8 channels can be
supported with an option to configure the board for a dual-channel application.
Figure 1: LCD Board (Bottom Side)
Heartbeat
LED
AVR
Processor
Main
Processor
Interface
Atmel
Programmer
Interface
Keypad
Interface
LCD Contrast
Adjust
Rotary Knob
Interfaces
Keypad
Matrix
Configuration
Jumper
NOTE: LCD Module and Status LEDs are mounted on reverse side.
Serial
Debug Port
Local
Reset