Relay Output Board
Relay Count
Dual-Configuration: (2)
Quad-Configuration: (4)
Contact
Configuration
Configuration: Single-Pole, Double-Throw
Contacts: Normally-Open (NO), Common, Normally-Closed (NC)
Switching
Capacity
3A @ 250 VAC or 30 VDC Resistive / 1 A Pilot Duty
NOTE: Inductive loads are not recommended.
Configuration
Options
Enable/Disable: If enabled, the selected relay
’s switching state
will respond
to defined parameters. If disabled, the relay will remain in the negated (de-
energized) state.
Units: Selectable Setpoint units of Pound (lb), Kilogram (kg), Gallon (gal),
or Liter (L).
Programmable Setpoints: User-defined, net-measurement thresholds that
will trigger relay switching.
Low or High: Defines whether relay assertion will occur in the net-
measurement region below (Low) or above (High) the programmable
Setpoint value.
Free-Run or Latch: Defines whether assertion of the selected relay will
continuously track the current net-measurement (Free-Run), or if an
assertion state will remain latched once asserted, regardless of current net-
measurement, until the user resets its state (Latch).
Trigger Alarm: Defines whether assertion of the selected relay will assert
the system alarm state.
3
Assembly and Set-Up Instructions
Carefully read this entire section and the section titled
all of the system components before making permanent changes to the Control-Panel enclosure.
Attention should be given to known requirements as well as the future possibility of upgrading a single-
channel configuration into a dual-channel measurement system if applicable.