Power:
120 Volt, 50/60 Hz single phase, 0.5 amps. 240 Volt available with jumpers on board.
Dimensions:
35.00” deep maximum x 30.25” wide maximum x 11.13” high approximate.
Bladder model extends the width dim6.00”. See deployment area for bladder below.
III.
Assembly and Start-Up:
The set up procedure is as follows:
1.
Locate a solid, relatively level spot on the floor to install scale platform. Clean all debris
that may interfere with scale clearance. Use the adjustable load cell leveling foot to level
the base unit from front to back, and tighten the nut against the cell to prevent movement.
VERY IMPORTANT: If you are using the Model 4042WB-ECO™, make sure that expandable
bladder has room and clearance to expand without coming into contact with any other objects
that may cause a leak or obstruct proper expansion of the bladder!!!
2.
If conduit is used, about 2’ of horizontal, flexible conduit should be connected horizontally to
frame before using rigid conduit.
3. The scale is calibrated at the factory with certified test weights and should not need
calibrating when installing!
4.
Mount digital indicator to wall and attach conduit for load cell cable and output signals as
required.
5.
Connect load cell cable from load cell, or junction box, to TB-1 as follows:
TB1: 1: Low Level set pt. 1 (REED relay, contact closure to pin 2: common)
2: Common
3: Low Level set pt. 2 (REED relay, contact closure to pin 2: common)
*
4: 4-20 LOOP Powered (4 is common and 5 is supply)
*
5:
*
6: 4-20 SCALE Powered (5 is common and 6 is supply)
7: - Sense (optional)
8: - Excitation (BLACK)
9: + Sense (optional)
10: + Excitation (RED)