Date / time setting procedure

- Under power-off mode, please press the ”SET Button” to 
enter date / time setting procedure and the month value 
will be flashed first.     
- To adjust the value of month, please press ”MEM Button” 
and the value of month, please press ”MEM Button” and 
the   value   will   go   up.   Once   finished,   please   press  ”SET 
Button” again to confirm the set value and go to the next 
setting.
- Follow the steps instructed above to adjust the value of 
date and time consquentty.

Setting the alarm clock

The SC 6360 features an alarm clock. The alarm can be 
set to ring at three different times in the day. The alarm is 
especially   helpful   it   you   are   required   to   measure   your 
blood pressure at specific times (for example 7:00 a.m., 
12:00 p.m. and 10:00 p.m.) Fig. 1 – 3.

6

Instructions for measuring the blood pressure 

In order to obtain comparable values, always measure the 
blood pressure under the same conditions, i.e. in a relaxed 
atmosphere,   not   after   the   consumption   of   alcohol,   not 
during a meal and not after being exposed to physical or 
nervous stress.
If possible, make the measurement while being seated

 

at a 

table and only with your left upper arm stripped.

The blood pressure measurement

Put the cuff around your 

left

 upper arm in such a way that 

the tube is directed towards the bend of the elbow, with the 
lower cuff edge ending about 2 cm above the bend of the 
elbow.   Now   connect   the   cuff   with   the   instrument   by 
plugging the air plug at the tube of the cuff into the socket 
on the left side of the instrument.
 

                    

The cuff should be 

                    

reasonably tight.

Start the measurement by pressing the ON/OFF-button.

If  you press  the ON/OFF-button  after  the measurement, 
the instrument will transfer the values automatically to the 
memory.

Premature discontinuation of the measurement

The measurement of the blood pressure can be discontinued 
at any time by pressing the ON/OFF-button. The instrument 
will then deflate the cuff immediately. 

8

  

Periodic re-calibration

We   recommend   re-calibrating   the   pressure   display 
regularly every 2 years. 

Error messages and disturbances

Should   an   error  occur  during  a  measurement,   the   word 
„Err“ and a symbol (code for Customer Services) will be 
displayed. 
We know from long-standing experience that a fault has 
mainly   been   provoked   by   handling   the   instrument 
incorrectly.   The   most   frequent   sources   of   faults   are 
agitated   movements   during   the   measurement,   the 
incorrect placement of the cuff or the use of the wrong type 
of batteries or accumulators.
The   measurement   should   be   repeated   after   5   min   the 
earliest.

      
       Disposal instructions 

Batteries shall be properly disposed of. Use the relevant 
collection   bins   the   battery-selling   trade   as   well   as 
municipal collecting points provide for this purpose.
Please   dispose   the   instrument   properly   in   a   municipal 
collection point for disused electrical equipment after the 
end of its useful life.

11

Memory recall and deletion

Memory recall

The blood pressure monitor SC 6360 can store up to 60 
sets of memory. To recall the memory, please press the 
”MEM   Button”   under   power-off   mode   first.   Then,   the 
average   measurement   result   will   be  shown   on   the   LCD 
first. After the average reading is shown on the display, 
you can press the ”MEM Button” to track historical recards 
from number 1 to number 60. Or press ”SET Button” to 
track from number 60 to number 1.

Memory deletion

To   clear   all   the   memory   records,   please   press   ”MEM 
Button” and hold it until the screen shows Ctr.
This function only operates under power off mode.

What blood pressure values are normal?

The blood pressure is too high, when the diastolic value 
exceeds 90 mmHg and/or the systolic value 160 mmHg in 
relaxed conditions.
The   World   Health   Organization   (WHO)   recommends 
medical treatment, when the diastolic value exceeds 100 
mmHg.   The   doctor   should   also   be   consulted   when   the 
blood   pressure   is   too   low,   i.e.   when   the   systolic   value 
drops below 105 mmHg and/or the diastolic value below 
60 mmHg.