SBS-4815CT USER MANUAL
17
/
30
Table
Chart
Preset
4.6 Check the Connection of the Wireless Modules
4.6.1
Press “BatteryView” on the main menu to enter the table interface, if all
wireless modules are connected correctly, you will see the voltage of each cell. If the
voltages of some cells are not showing, please re-check the wireless module
connections.
4.6.2
Press “Chart” to see the histogram for each cell in the string.
4.6.3
Both the table and chart interfaces show 24 cells at a time. If the tested battery
string has more than 24 cells, press the “Next” & “Prev” to see the other cells.
4.6.4
Press “Exit” to go back to the main menu
4.7 The Preset Function
4.7.1
The preset function allows 30 programmable locations to save discharge test
setups. You can select any of the preset tests and press “Apply” to use those
discharge parameters.
The SBS-4815CT supports manual setting in the discharge
interface without using the preset features.
Press “Preset” on the main menu to enter the preset interface
Back to the main menu
One screen can show 24 cells
If over 24 cells, press “Next” “Prev”
to see more
Preset parameter number
AhRate: The rated capacity of
the tested battery string
HourRate: The hour rate of
discharge
TestCurr: discharge current
BattSum: cell qty in battery
string
#Strings: string qty for single
discharge test
The highest & lowest voltage
cell in battery string
#BattLow: qty of cells which
voltages below “BattLowV”