Quanta series
– Hardware Manual
QUANTAHM.1.2
3. Quanta Mechanical and Electrical integration
3.1. Quanta Mechanical specifications
The table below summarizes all mechanical and environmental specifications.
Item
Specification
Size
78.7 x 51.5 x 22.2 mm
Weight
75g (internal IMU)
65 g (external IMU)
Shocks
500 g for 0.3 ms
Operating Vibrations
8g RMS – 20Hz to 2 kHz as per MIL-STD-810G
Operating temperature
-40 to 71 °C
Storage
-40 to 85°C
Humidity
MIL-STD-810G, Method 507.5 Procedure II (95%)
MTBF (computed)
50,000 hours
3.1.1. Reference coordinate frame
The following reference coordinate frame should be considered when measuring the lever arms and distances
from the product to the point of interest (eg. GNSS antenna).
12/48
Figure 3.1: Quanta coordinate frame (internal IMU)
X
Y
Z