SPECIFICATIONS OF CONTROLLER

Power supply, power 

consumption, and current 

consumption

See PCD7.LRxx-P5 

Room Controllers – Installation & Com-

missioning Instructions (PP31-406)

Ambient temperatur

See picture 0G.

Storage temperature

See picture 0B.

Humidity

5 … 95 % r.h. non-condensing

Dimensions

See pictures 0C, 0E.

Degree of protectio

IP20

IP30 (when mounted with accessory 

IRM-RSC or 

IRM-RLC)

RECOMMENDATIONS AND RULES

 

Rules regarding electrostatic discharge should be followed.

 

► If the device is modified in any way, except by the manu

-

facturer, all warranties concerning operation and safety are 

invalidated.

 

Make sure that the local standards and regulations are 

observed at all times. Examples of such regulations are VDE 

0800 and VDE 0100 or EN 60204-1 for earth grounding.

 

Use only accessory equipment which comes from or has been 

approved by Honeywell.

 

It is recommended that the device be kept at room temper-

ature for at least 24 hours before applying power. This is to 

allow any condensation resulting from low shipping / storage 

temperatures to evaporate.

 

The device must be installed in a manner (e.g., in a lockable 

cabinet) ensuring that uncertified persons have no access to 

the terminals.

 

Do not open the device, as it contains no user-serviceable 

parts inside!

 

The device is suitable for mounting in fuse boxes conforming 

to standard DIN 43880, and having a slot height of max. 

45

 

mm.

 

The device is suitable for panel rail mounting on 35

 

mm 

standard panel rail (both horizontal and vertical rail mounting 

possible) – see pictures 0G and 0H.

STANDARDS, APPROVALS, ETC.

PURPOSE OF CONTROL: OPERATING CONTROL and 

multifunctional non-safety control intended for HVAC in home 

(residential, commercial, and light-industrial) environments

 

24

 

V models: 

UL 60730-1, Standard for Automatic Electric Controls for 

Household and Similar Use, Part 1: General Requirements

 

CE-approved

 

FCC part 15B-compliant.

CONSTRUCTION OF CONTROL: Independently mounted 

electronic control unit with fixed wiring. Panel-mounted on a 

DIN rail.

SHOCK PROTECTION: Class II.

POLLUTION DEGREE: 2.

RATED IMPULSE VOLTAGE:

 

230

 

V circuits: 2500

 

V

 

  24

 

V circuits: 500

 

V

NOTE:

   Keep AC mains supply/load cables separate from 

signal wiring!

RELAY SPECIFICATIONS

CAUTION

RISK OF ELECTRICAL SHOCK OR EQUIPMENT DAMAGES! 

It is not permitted to combine low voltage and line voltage in 

the relay block.

Содержание Saia PG5

Страница 1: ...R1 1 L 2 N 3 24V 4 24V0 5 24V 6 24V0 7 TN 8 T 9 TO0 10 TN 11 TO1 12 TO2 13 TN 14 TO3 15 RO3 16 RO3 17 IN3 18 RN 19 RN 20 IN0 21 RO0 22 IN1 23 RO1 24 IN2 25 RO2 DA 26 DB 27 GND 28 24V 29 DA 62 DB 63 GND 64 WM1 30 WM2 31 AO0 32 AO1 34 AO2 36 AO3 38 AO4 40 AO5 42 GND 33 24V 35 GND 37 24V 39 GND 41 24V 43 24V 44 GND 46 UI1 48 UI2 50 GND 52 UI5 54 LED 45 UI0 47 GND 49 UI3 51 UI4 53 GND 55 UI6 56 GND 58...

Страница 2: ...5 1 5 0 5 RO3 IN3 RN RN IN0 RO0 IN1 RO1 IN2 RO2 RUN HALT Sylk Bus RS485 Port 1 UI0 0 10V GND Dig NTC V TN T TO0TNTO1 TO2 TNTO3 RS485 Port 0 C1 D A D B GND C1 AO0 GND 0 10V V Power Supply 24 VAC Out 230 V 24 VAC USB T2 R2 T1 R1 IRM RLC BULK PACK 10 pcs PCD7 LRLx 54 59 58 4 58 4 162 198 54 54 59 0E DIMENSIONS PCD7 LRSx P5 0F OPTIONAL FOR IP30 PCD7 LRSx P5 AO0 GND 0 10V V UI0 0 10V GND Dig NTC V RS48...

Страница 3: ...O2 RUN HALT Sylk Bus RS485 Port 1 UI0 0 10 V GND Dig NTC V TN T TO0TNTO1 TO2 TNTO3 RS485 Port 0 C1 D A D B GND C1 AO0 GND 0 10V V Power Supply 24 VAC Out 230 V 24 VAC USB T2 R2 T1 R1 1 L 2 N 3 24V 4 24V0 5 24V 6 24V0 7 TN 8 T 9 TO0 10 TN 11 TO1 12 TO2 13 TN 14 TO3 15 RO3 16 RO3 17 IN3 18 RN 19 RN 20 IN0 21 RO0 22 IN1 23 RO1 24 IN2 25 RO2 DA 26 DB 27 GND 28 24V 29 DA 62 DB 63 GND 64 WM1 30 WM2 31 A...

Страница 4: ...4 Saia Burgess Controls AG PCD7 LRxx P5 PG5 ROOM CONTROLLER MOUNTING INSTRUCTIONS 2 DIN RAIL MOUNTING PCD7 LRxx P5 MOUNTING IRM RxC CLICK 1 3 4 5 2 6 3 DISMOUNTING IRM RxC DISMOUNTING PCD7 LRxx P5 from DIN RAIL 1 3 2 4 5 6 ...

Страница 5: ...0 VAC SylkBus AOs UIs RS485 24 VAC BOs TRs 24 230 VAC BOs ROs 24 230 VAC 0 0 RS485 CAUTION RISK OF EQUIPMENT DAMAGE AND OR PERSONAL INJURY DO NOT USE TERMINALS 3 4 OF 230 V MODELS 24VAC POWER OUTPUT FOR AUXILIARY DEVICES AS A POWER INPUT On the PCD7 LRL5 P5 the Power Supply pin 3 4 is the 24VAC power input of the controller 4C PCD7 LRS4 P5 WIRING 230 V MODELS 4D PCD7 LRS5 P5 WIRING 24 V MODELS AO0...

Страница 6: ...0100 or EN 60204 1 for earth grounding Use only accessory equipment which comes from or has been approved by Honeywell It is recommended that the device be kept at room temper ature for at least 24 hours before applying power This is to allow any condensation resulting from low shipping storage temperatures to evaporate The device must be installed in a manner e g in a lockable cabinet ensuring th...

Отзывы: