Main menu
EXIT
Exit menu.
CLEAN ELECTRODES
Run the clean program to remove dirt on electrodes.
This should be done at least every 20
th
splice.
CALIBRATE
Start automatic environmental compensation.
This should be done every time the environment changes.
The splicer will adjust this calibration a small step every
splice but when changing environment this calibration will
be needed. To prepare for this calibration strip and clean a
piece of fiber and place it all the way through the v-grove
and then start the calibration. The PWR value will be updated.
TURN OVEN ON
Manually run the oven program. Normally, when a splice is done
next step is to move the fiber with a sleeve to the oven and press
the
OVEN
button.
SETUP
Setup various things shown below.
INFO
Shows miscellaneous information of the splicer.