Thank you for purchasing this light fitting. Please read the instructions carefully before use to ensure safe and 
satisfactory operation of this product. Please retain these instructions for future reference.

Warning

This light fitting is Class 1 and must be connected to 
an Earth circuit

Please read these instructions carefully before 
commencing any work.

This unit must be fitted by a competent and qualified 
electrician.

Install in accordance with IEE Wiring regulations and 
current Building Regulations.

To prevent electrocution switch off at mains supply 
before installing or maintaining this fitting. Ensure 
other persons cannot  restore the electrical supply 
without your knowledge. If you are in any doubt, 
please consult a qualified electrician.

This light fitting should be connected to a circuit with a 
30mA RCD fitted.

If replacing an existing fitting, make a careful note of 
the connections.

This system contains non-replaceable parts and 
cannot be serviced. If damage occurs the part should 
be scrapped.

Waste electrical products should not be disposed of 
with household waste. Please recycle where facilities 
exist. Check with your local authority or retailer for 
recycling advice.

This product is rated at IP44.

This product is not suitable for dimming.

The entire unit gets hot whilst on for a period of time.

Specification

Voltage: 

240V 50Hz a.c.

Lamp: 

6W LED Module - 6000K/600lm 

IP rating: 

44

Layout

Installation & Wiring

Check that...

•  You have correctly identified the wires.
•  The connections are tight.

•  No loose strands have been left out of the connection 

block.

•  Plan the desired layout of this fitting carefully, 

ensuring the cables will reach the distance between 
the junction box and the light fitting

•  Avoid locating any cables in positions that would  

cause a hazard. Position cables and junction boxes 
(not supplied) away from areas where they may be 
at risk from being cut, trapped or damaged

•  Cables in walls must be protected using suitable 

conduit or plastic trunking. 

•  The mains supply cable must have a minimum cross 

sectional area of 1.0mm²

•  This product has special protection against the 

ingress of moisture and is IP44 rated.

Existing fittings must be completely removed before 
installation of a new product. Before removing the 
existing fitting, 

carefully note the position of each set 

of wires

.

•  Remove the lampshade from the product using a 

screwdriver.

•  Unscrew Screw A and remove the Transparent 

Terminal Cover.

•  Hold the product in position and mark the location 

of the fixing holes. Sensor must be at the base, as 
shown below..

•  Thread the cable through the rubber grommet in the 

back plate.

•  Fix the wall back to the wall using the screws 

and plugs supplied. Ensure the wall is capable of 
holding the weight of the product. Take care to avoid 
damaging any concealed wiring and pipes. The 
correct fixings should be used for brick or cavity 
walls.

•  Wire as detailed below.

Wiring Colours :-
L (Live) - Brown
N (Neutral) - Blue
Earth         - Green/
                   Yellow

SWITCHED LIVE

NEUTRAL (BLUE) 

 

EARTH (GREEN/YELLOW) 

BROWN (L)

NEUTRAL (N)

GREEN/YELLOW

SUPPLYL

IGHT FITTING

Commissioning

•  Reattach the terminal cover and diffuser. 

•  Replace fuse or circuit breaker and switch on. Your 

light is now ready for use.