Thank you for purchasing this light fitting. Please read the instructions carefully before use to ensure safe and satisfactory
operation of this product. Please retain these instructions for future reference.
Warning
This light fitting is Class 1 and must be connected to
an Earth circuit
Please read these instructions carefully before
commencing any work.
This unit must be fitted by a competent and qualified
electrician.
Install in accordance with IEE Wiring regulations and
current Building Regulations.
To prevent electrocution switch off at mains supply
before installing or maintaining this fitting. Ensure other
persons cannot restore the electrical supply without
your knowledge. If you are in any doubt, please consult a
qualified electrician.
This light fitting should be connected to a circuit with a
30mA RCD fitted.
If replacing an existing fitting, make a careful note of the
connections.
This system contains non-replaceable parts and cannot be
serviced. If damage occurs the part should be scrapped.
Waste electrical products should not be disposed of with
household waste. Please recycle where facilities exist.
Check with your local authority or retailer for recycling
advice.
This product is rated at IP54.
This product is not suitable for dimming.
This product is not suitable for location in or near a
marine or sea environment.
Specification
Voltage:
240V 50Hz a.c.
Lamp:
9W LED (SMD 5630)
IP rating:
54
Layout
Installation
Having correctly identified the wiring from your existing light
fitting, connect to the connection block inside the product in
the following way:
Wiring
Check that...
• You have correctly identified the wires.
• The connections are tight.
• No loose strands have been left out of the connection
block.
• The lid has been refitted on to the connection block case
• Plan the desired layout of this fitting carefully, ensuring
the cables will reach the distance between the junction
box and the light fitting
• Avoid locating any cables in positions that would
cause a hazard. Position cables and junction boxes (not
supplied) away from areas where they may be at risk
from being cut, trapped or damaged
• Cables in walls must be protected using suitable
conduit or plastic trunking.
• The mains supply cable must have a minimum cross
sectional area of 1.0mm²
• This product has special protection against the ingress
of moisture and is IP54 rated.
Existing fittings must be completely removed before
installation of a new product. Before removing the existing
fitting,
carefully note the position of each set of wires
.
• Remove the fixing bracket. Use it as a template (in a
horizontal position) to mark the fixing holes.
• Thread the cable through the middle hole.
• Fix the bracket to the wall using the screws and plugs
supplied Ensure the wall is capable of holding the
weight of the product. Take care to avoid damaging any
concealed wiring and pipes. The correct fixings should
be used for brick or cavity walls.
• Wire as detailed below.
NEUTRAL
EARTH (GREEN/YELLOW)
SWITCHED LIVE
BLUE (N)
GREEN/YELLOW
BROWN (L)
SUPPLY
LIGHT FITTING