Saxby Lighting Scimitar Series Скачать руководство пользователя страница 2

Thank you for purchasing this light fitting. Please read the instructions carefully before use to ensure safe and 
satisfactory operation of this product. Please retain these instructions for future reference.

Warning

This is a Class 1 product and must be earthed.

Please read these instructions carefully before 
commencing any work.

This unit must be fitted by a competent and qualified 
electrician.

Install in accordance with IEE Wiring regulations and 
current Building Regulations.

To prevent electrocution switch off at mains supply 
before installing or maintaining this fitting. Ensure 
other persons cannot 

 

restore the electrical supply 

without your knowledge. If you are in any doubt, 
please consult a qualified electrician.

This light fitting should be connected to a circuit with a 
30mA RCD fitted.

If replacing an existing fitting, make a careful note of 
the connections.

The unit cannot be dimmed.

This system contains non-replaceable parts and 
cannot be serviced. If damage occurs the part should 
be scrapped.

Waste electrical products should not be disposed of 
with household waste. Please recycle where facilities 
exist. Check with your local authority or retailer for 
recycling advice.

This product is not suitable for location in or near a 
marine environment.

The entire unit gets hot whilst on for a period of time.

Terminal block not included. 

 

Installation may require 

advice from a qualified person.

Specification

Voltage: 

240V

 ~ 50Hz

Lamp: 

 10W LED Module - IP65

 

73452:

73451:

 10W LED Module - IP44

 

73453: 10W LED Module - IP65

 

73454: 10W LED Module - IP44

 

73455: 30W LED Module - IP65

 

73456: 30W LED Module - IP44

 

73457: 30W LED Module - IP65

 

73458: 30W LED Module - IP44

 

73459: 50W LED Module - IP65

 

73460: 50W LED Module - IP44

 

73461: 50W LED Module - IP65

 

73462: 50W LED Module - IP44

Layout

•  Plan the desired layout of this fitting carefully, 

ensuring the cables will reach the distance between 
the junction box and the light fitting.

•  Avoid locating any cables in positions that would 

cause a hazard. Position cables and outdoor rated 
junction boxes (not supplied) away from areas 
where they may be at risk from being cut, trapped or 
damaged.

•  This product is supplied with 1.5 metres of H05RN-F 

outdoor grade rubber sheathed cable - ready for 
connection to an approved, outdoor rated terminal 
block which is not supplied and must be obtained.

•  Cables must be protected using suitable conduit or 

plastic trunking.

•  This is a floodlight product, and therefore should be 

positioned where it will not cause a glare hazard.

Existing fittings must be completely removed before 
installation of a new product. Before removing the 
existing fitting, 

carefully note the position of each set 

of wires

.

•  Decide on the optimum location for the product. For 

PIR versions, the optimum height is between 1.8-
2.5m

•  Hold the product in position and mark the location 

of the fixing holes. A minimum of two fixing points 

must be used. Ensure the wall is capable of holding 
the weight of the product. The bracket can be 
removed from the fitting for ease of installation

•  Drill and plug the wall at the marked positions.

•  Fix the bracket to the wall using the screws 

provided and plugs. Take care to avoid damaging 
any concealed wiring and pipes. The correct fixings 
should be used for brick or cavity walls.

•  Wire as detailed below.

Installation

NEUTRAL 

EARTH    

 

SWITCHED LIVE 

BLUEN )

GREEN/YELLOW

BROWN (L)

SUPPLY

LIGHT FITTING

Terminal block not included. 

 

Installation may require advice from a qualified person. 

 

Connect to an approved 

outdoor rated terminal block, observing the wiring diagram here:-

Wiring

Check that...

•  You have correctly identified the wires.
•  The connections are tight.

•  No loose strands have been left out of the connection 

block.

•  Refit the cover on the IP terminal block. Ensure that 

the seals are correctly located, and refit the screws.

•  Using the supplied allen key, loosen the bolts on the 

side,  and  adjust  the  fitting  to  the  desired  position. 
Ensure that the cable is not snagged. Re-tighten the 
bolts.

•  Replace  fuse  or  circuit  breaker  and  switch  on.  Your 

light is now ready for use.

Commissioning